Image 53

HPMA Audit Message Reference

FSTG—File Store to Grid

When new content is stored via the FSG, the content is cached locally by the FSG server and is copied into the grid. When the grid confirms it has stored the copy (and is processing it under its business rules for replication), this message is issued.

Table 36: FSTG—File Store to Grid Fields

Code

Field

Description

 

 

 

FPTH

File path

The complete path and name of the file being stored.

 

 

 

FLTP

File Type

Indicates the type of object storage, as processed by the

 

 

grid’s file type detection.

 

 

 

UUID

Universal Unique

The identifier of the file content within the grid.

 

ID

 

 

 

 

RSLT

Result Code

The result of the storage operation:

 

 

SUCS—Successfully stored.

 

 

FTER—Failed extended type verification (will be re-

 

 

ingested as a generic object).

 

 

TOUT—Failed due to timeout.

 

 

ERRC—Failed due to lost connection.

 

 

GERR—A general error occurred while storing content.

 

 

 

If a failure is logged, the FSG initiates a new storage attempt. Retries continue until successful.

FSWI—File Swap In

A file has been retrieved from the grid for storage in the FSG local cache. Content still resides in the grid.

Table 37: FSWI—File Swap In Fields

Code

Field

Description

 

 

 

FPTH

File path

The complete path and name of the file added to the FSG

 

 

local cache.

 

 

 

UUID

Universal Unique

The identifier of the file content within the grid.

 

ID

 

 

 

 