exclude from discovery. Separate additional serial numbers with a comma, as shown by the following example:

cimom.symmetrix.exclude=000183500570,000183500575

where 000183500570 and 000183500575 are serial numbers for Symmetrix storage systems.

7.When you are done, click Save.

8.Restart the service for the management server for your changes to take effect.

While AppStorManager is restarting, users are not able to access the management server. The AppStorManager service must be running for the management server to monitor elements.

Discovering EMC CLARiiON Storage Systems

The EMC Navisphere® CLI must be installed on the management server for the management server to communicate with the CLARiiON® storage system. At the time this documentation was created, EMC distributed the Navisphere CLI as part of the EMC Navisphere Software Suite. Contact your EMC representative for more information about obtaining the Navisphere CLI. Distribution rights for the Navisphere CLI belong to EMC. For Solaris, you must install the Navisphere Disk Array Management Tool CLI (NAVICLI).

Contact your EMC representative for more information about obtaining the Navisphere CLI. Distribution rights for the Navisphere CLI belong to EMC.

IMPORTANT: Before you discover your CLARiiON storage systems, you must have already installed all required software components for your CLARiiON storage system, such as the Navisphere Host Agent. Refer to the documentation for your storage system for more information.

In Navisphere Manager add one of the following to the privilege user section:

SYSTEM@name_of_my_management_server

SYSTEM@IP_of_my_management_server

where

name_of_my_management_server is the DNS name of the computer running the management server software

IP_of_my_management_server is the IP address of the computer running the management server software

When you use the management server to discover the CLARiiON storage system, provide the IP address for the CLARiiON storage system and the user name and password used to log into Navisphere.

Discovering Engenio Storage Systems

Keep in mind the following when discovering an Engenio storage system:

Discover all controllers on an Engenio storage system by entering the IP address of each controller.

Storage Essentials 5.00.01 User Guide 59