MA7200 PLUS Inverter 1 to 2 HP PID Fan and Pump Quick Start Manual

__________________________________________________________________

To set parameter Bn-18 = 005.00

(Integral Time )

Keypad Steps

1 - Press the key

2 - Press the EDIT key

ENTER

3 - Press the

RESET

key twice; then the

key

4 - Press the

RESET

key ; then the

key 5 times

Resulting Display

Bn-18

PID I_ Time

Flashing

Bn-18 = 010.00 s

PID I_ Time

Flashing

Bn-18 = 000.00 s

PID I_ Time

Flashing

Bn-18 = 005.00 s

6 - Press the

EDIT

key to save.

ENTER

PID I_ Time

Entry Accepted

2 Seconds

7 - Press the

PRGM

key to return to the main display.

DRIVE

Flashing

Bn-18 = 005.00 s

PID I_ Time

Word About PID Control-

________________________________________________________________ 14

TECO – Westinghouse Motor Company