Operating advanced function
FIELD SETTING MODE
DHW Heating : Code 30✴✴
TU > THP MAX |
|
| |||
T(C) |
| TU |
|
| |
#3021 |
|
|
|
| |
|
|
|
| ||
|
| THP MAX |
| #3022 | |
|
|
| |||
|
|
| THP OFF |
| #3023 |
|
|
|
| ||
|
|
| THP ON |
|
|
|
|
|
|
| |
|
|
|
|
|
|
TU < THP MAX
T(C)
#3021 |
| THP MAX |
|
TU=THP OFF
THP ON
Tu : User set temp.
T(C) : Temp. (Celcius)
#3023
1
Heating request 0
1
DHW request 0
DHW(H/P) 1 operation 0
#3024
#3025 #3026
t
Field Setting Value
Main Menu & | Sub Menu Function | Description | Sub | Default | Min | Max | Step | Unit | |
Code | Code | ||||||||
|
|
|
|
|
|
| |||
DHW | Domestic Hot Water | Application | ✴✴11 | 0(No) | 0 | 1(Yes) | - | - | |
| Tank | ||||||||
Code 30✴✴ |
|
|
|
|
|
|
| ||
Heat Pump | Max Temp | ✴✴21 | 50 | 45 | 55 | 1 | ˚C | ||
| |||||||||
|
| Stop | ✴✴22 | 2 | 2 | 10 | 1 | ˚C | |
|
| Start | ✴✴23 | 5 | 1 | 20 | 1 | ˚C | |
|
| Min Operation | ✴✴24 | 5 | 0 | 20 | 1 | min | |
|
| Max Operation | ✴✴25 | 30 | 5 | 95 | 5 | min | |
|
| Interval | ✴✴26 | 3 | 0 | 10 | 0.5 | hour | |
| Booster Heater | Application | ✴✴31 | 1(On) | 0(Off) | 1 | - | - | |
|
| Delay Time | ✴✴32 | 20 | 20 | 95 | 5 | min | |
|
| Overshoot | ✴✴33 | 0 | 0 | 4 | 1 | ˚C | |
|
| Compensation Temp | ✴✴34 | 10 | 0 | 20 | 1 | ˚C | |
| Disinfection | Application | ✴✴41 | 1(On) | 0(Off) | 1 | - | - | |
|
| Interval | ✴✴42 | Fri | Mon | Sun | 1(All) | day | |
|
| Start Time | ✴✴43 | 23 | 0 | 23 | 1 | o'clock | |
|
| Target Temp | ✴✴44 | 70 | 40 | 70 | 5 | ˚C | |
|
| Duration | ✴✴45 | 10 | 5 | 60 | 5 | min | |
| Power DHW by User | Timer OFF Function | ✴✴51 | 0(Off) | 0 | 1 | - | - | |
| Input | Timer Duration | ✴✴52 | 60 | 30 | 300 | 10 | min | |
| Solar Panel | H/P Combination | ✴✴61 | 0(No) | 0(No) | 1(Yes) | - | - |