•Code 30✴✴ : User’s options for domestic hot water(DHW) tank heating 3011 : Application of DHW tank in user’s system
302✴ : Heat pump variables for tank temp. control and combination with booster heater
303✴ : Booster heater variables for combination with heat pump
304✴ : Periodical disinfection heating of water tank
305✴ : Off timer for power DHW mode by hot key of wired remote controller
3061 : Combination of external field solar panel for with heat pump for DHW heating
Field Setting Value
Main Menu & | Sub Menu Function | Description | Sub | Default | Min | Max | Step | Unit | |
Code | Code | ||||||||
|
|
|
|
|
|
| |||
DHW | Domestic Hot Water | Application | ✴✴11 | 0(No) | 0 | 1(Yes) | - | - | |
| Tank | ||||||||
Code 30✴✴ |
|
|
|
|
|
|
| ||
Heat Pump | Max Temp | ✴✴21 | 50 | 45 | 55 | 1 | ˚C | ||
| |||||||||
|
| Stop | ✴✴22 | 2 | 2 | 10 | 1 | ˚C | |
|
| Start | ✴✴23 | 5 | 1 | 20 | 1 | ˚C | |
|
| Min Operation | ✴✴24 | 5 | 0 | 20 | 1 | min | |
|
| Max Operation | ✴✴25 | 30 | 5 | 95 | 5 | min | |
|
| Interval | ✴✴26 | 3 | 0 | 10 | 0.5 | hour | |
| Booster Heater | Application | ✴✴31 | 1(On) | 0(OFF) | 1 | - | - | |
|
| Delay Time | ✴✴32 | 20 | 20 | 95 | 5 | min | |
|
| Overshoot | ✴✴33 | 0 | 0 | 4 | 1 | ˚C | |
|
| Compensation Temp | ✴✴34 | 10 | 0 | 20 | 1 | ˚C | |
| Disinfection | Application | ✴✴41 | 1(On) | 0(OFF) | 1 | - | - | |
|
| Interval | ✴✴42 | Fri | Mon | Sun | 1(All) | day | |
|
| Start Time | ✴✴43 | 23 | 0 | 23 | 1 | o'clock | |
|
| Target Temp | ✴✴44 | 70 | 40 | 70 | 5 | ˚C | |
|
| Duration | ✴✴45 | 10 | 5 | 60 | 5 | min | |
| Power DHW by User | Timer OFF Function | ✴✴51 | 0(Off) | 0 | 1(On) | - | - | |
| Input | Timer Duration | ✴✴52 | 60 | 30 | 300 | 10 | min | |
| Solar Panel | H/P Combination | ✴✴61 | 0 | 0 | 1(Yes) | - | - |