Operating advanced function
FIELD SETTING MODE
Field Setting Value(FSV) Table
•Code 40✴✴ : User’s options for heating devices including internal backup heater and external boiler 401✴ : Space/DHW heating priority and control variables
402✴ : Backup/Booster heater priority and control variables
403✴ : Additional backup boiler operating variables
•Code 50✴✴ : User’s options for extra functions
501✴ : New target temperatures of each mode by “Outgoing” hot key of remote controller
5021 : Temperature difference between before & after values in “Economic” DHW mode
503✴ :
Field Setting Value
Main Menu & | Sub Menu Function | Description | Sub | Default | Min | Max | Step | Unit | |
Code | Code | ||||||||
|
|
|
|
|
|
| |||
Heating | Heat Pump | Heating/DHW Priority | ✴✴11 | 0(DHW) | 0 | 1(Heating) | - | - | |
Code 40✴✴ |
| Outdoor Temp for Priority | ✴✴12 | 0 | 20 | 1 | ˚C | ||
| Heating Off | ✴✴13 | 25 | 14 | 35 | 1 | ˚C | ||
|
| ||||||||
|
| Overshoot | ✴✴14 | 2 | 1 | 4 | 1 | ˚C | |
| Backup Heater | Application | ✴✴21 | 1(On) | 0(Off) | 1 | - | - | |
|
| BUH/BSH Priority | ✴✴22 | 0(Both) | 0 | 2(BSH) | 1 | - | |
|
| For | ✴✴23 | 1(On) | 0(Off) | 1 | - | - | |
|
| Threshold Temp | ✴✴24 | 0 | 35 | 1 | ˚C | ||
| Backup Boiler | Application | ✴✴31 | 0(No) | 0 | 1(Yes) | - | - | |
|
| Boiler Priority | ✴✴32 | 0(Off) | 0 | 1(On) | - | - | |
|
| Threshold Temp | ✴✴33 | 5 | 1 | ˚C | |||
Others | Outing | Water Out Temp for | ✴✴11 | 25 | 5 | 25 | 1 | ˚C | |
|
| Cooling | |||||||
Code 50✴✴ |
|
|
|
|
|
|
| ||
| Room Temp for Cooling | ✴✴12 | 30 | 18 | 30 | 1 | ˚C | ||
|
| ||||||||
|
| Water Out Temp for | ✴✴13 | 25 | 15 | 55 | 1 | ˚C | |
|
| Heating | |||||||
|
|
|
|
|
|
|
| ||
|
| Room Temp for Heating | ✴✴14 | 16 | 16 | 30 | 1 | ˚C | |
|
| Auto Cooling WL1 Temp | ✴✴15 | 25 | 5 | 25 | 1 | ˚C | |
|
| Auto Cooling WL2 Temp | ✴✴16 | 25 | 5 | 25 | 1 | ˚C | |
|
| Auto Heating WL1 Temp | ✴✴17 | 15 | 15 | 55 | 1 | ˚C | |
|
| Auto Heating WL2 Temp | ✴✴18 | 15 | 15 | 55 | 1 | ˚C | |
|
| Target Tank Temp | ✴✴19 | 30 | 30 | 70 | 1 | ˚C | |
| DHW Saving Mode | Temp Difference | ✴✴21 | 5 | 0 | 40 | 1 | ˚C | |
| TDM Variable | A2A Max Operation Time | ✴✴31 | 30 | 5 | 60 | 5 | min | |
|
| A2W Min Operation Time | ✴✴32 | 3 | 0 | 10 | 1 | min |
32_ Operating advanced function