Operating advanced function

FIELD SETTING MODE

Water Law & Room Thermostat : Code 20✴✴

 

Ts

 

 

 

Ts : Target Temp.

#2021/2031

 

 

Cooling WL

 

Ta : Ambient Temp.

 

 

 

 

#2022/2032

 

 

 

 

 

 

 

 

 

#2061/2071

 

 

 

 

 

 

 

 

 

Shift Value

#2062/2072

 

 

 

 

Heating WL

 

 

����������

Floor

FCU

 

 

 

 

 

 

 

 

 

 

#2011

#2012

#2051

#2052

Ta

 

 

 

 

 

 

Field Setting Value

Main Menu &

Sub Menu Function

Description

Sub

Default

Min

Max

Step

Unit

Code

Code

 

 

 

 

 

 

 

Water Law

Outdoor Temp for Water Law

Point

✴✴11

-10

-20

5

1

˚C

Code 20✴✴

(Heating)

Point

✴✴12

15

10

20

1

˚C

Water Out Temp for WL1 Heating

Point

✴✴21

40

40

55

1

˚C

 

 

(WL1-Floor)

Point

✴✴22

25

17

37

1

˚C

 

Water Out Temp for WL2 Heating

Point

✴✴31

50

40

55

1

˚C

 

(WL2-Fan Coil Unit)

Point

✴✴32

35

17

37

1

˚C

 

Heating Water Law for Auto Mode

WL Type

✴✴41

1(WL1)

1

2(WL2)

-

-

 

Outdoor Temp for Water Law

Point

✴✴51

30

25

35

1

˚C

 

(Cooling)

Point

✴✴52

40

35

45

1

˚C

 

Water Out Temp for WL1 Cooling

Point

✴✴61

25

18

25

1

˚C

 

(WL1-Floor)

Point

✴✴62

18

5

18

1

˚C

 

Water Out Temp for WL2 Cooling

Point

✴✴71

18

18

25

1

˚C

 

(WL2-Fan Coil Unit)

Point

✴✴72

5

5

18

1

˚C

 

Cooling Water Law for Auto Mode

WL Type

✴✴81

1(WL1)

1

2(WL2)

-

-

 

External Thermostat Application

#1(Floor)

✴✴91

0(No)

0

1(Yes)

-

-

 

#2(FCU)

✴✴92

0(No)

0

1(Yes)

-

-

 

 

Water Law for Heating

Outdoor air temperature range : Lower limit (#2011, Default -10˚C, Range : -20 ~ 5˚C), Upper limit (#2012, Default 15˚C, Range : 10 ~ 20˚C)

-With this default settings, the water outlet temperature by heating water law can be changed within the outdoor temperature range of -10 ~ 15˚C.

Water out temperature range for floor/FCU applications respectively :

Upper limit (#2021/2031, Default 40/50˚C, Range : 40 ~ 55˚C), Lower limit (#2022/2032,

Default 25/35˚C, Range : 17 ~ 37˚C)

-With this default settings, the water outlet temperature by heating water law can be changed within the range of 25/35 ~ 40/50˚C.

Type of water law for according to heating devices(floor/FCU) : #2041(Default “1”(WL1 for floor)), “2”(WL2 for FCU or radiator)

The #2 DIP switch in the wired remote controller should be set to “OFF”(Default) to control the water outlet temperature.

The operation mode of the wired remote controller should be set to “AUTO”() to use the weather dependent water law scheme.

34_ Operating advanced function

Page 34
Image 34
Samsung NH200WHXEA, NH200WHXES, NH160PHXEA, NH080PHXEA, NH300WHXEA Water Law & Room Thermostat Code, Water Law for Heating