Elevation scale

Setting coarse elevation The antenna pointing procedure begins with the steps described in this section and continues through the end of this chapter.

Follow the instructions in the order they are presented.

Set the initial (coarse) antenna elevation to the initial elevation value given by the installation software, as follows:

1.Loosen the two fine elevation adjustment nuts indicated in Figure 49 so the antenna reflector can move forward and backward.

2.Loosen the two elevation lockdown bolts indicated in Figure 49, a little at a time, until you can rotate the antenna reflector forward and backward to adjust the elevation.

Note: Do not tighten the elevation lockdown bolts yet because you will be adjusting elevation further, as explained in Fine elevation adjustment on page 62.

3.Set the elevation to the value given by the installation software.

Fine elevation adjustment nuts

Arrow indicates movement during elevation adjustment.

Elevation scale

Elevation lockdown bolts (2)

Figure 49: Setting coarse elevation