TROUBLESHOOTING

Risk of Unsafe Operation. Performing repairs may expose voltage sources, moving parts or compressed air sources.

Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure.

PROBLEM

CAUSE

CORRECTION

Excessive tank

Pressure switch does not

Move Off/Auto-On switch to

pressure - safety

shut off motor when

the "Off" position, if the unit

valve pops off.

compressor reaches "cut-

does not shut off contact a

 

out" pressure.

Trained Service Technician.

 

Pressure switch "cut-out"

Contact a Trained Service

 

too high.

Technician.

 

 

 

Air leaks at

Tube fittings are not tight

Tighten fittings where air can

fittings.

enough.

be heard escaping. Check

 

 

any exposed fittings with

 

 

soapy water solution. Do Not

 

 

Overtighten.

 

 

Apply sealant tape to threads

 

 

of exposed fittings.

 

 

 

Air leak from

Possible defect in safety

Operate safety valve

safety valve.

valve.

manually by pulling on ring.

 

 

If valve still leaks, Contact a

 

 

Trained Service Technician.

 

 

 

Knocking Noise.

Possible defect in safety

Operate safety valve

 

valve.

manually by pulling on ring.

 

 

If valve still leaks, Contact a

 

 

Trained Service Technician.

 

 

 

Pressure reading

It is normal for "some"

If there is an excessive

on the regulated

pressure drop to occur.

amount of pressure drop

pressure gauge

 

when the accessory is used,

drops when an

 

adjust the regulator following

accessory is

 

the instructions in the

used.

 

"Description of Operation"

 

 

paragraph in the "Operation

 

 

Section.

 

 

NOTE: Adjust the regulated

 

 

pressure under flow

 

 

conditions (while accessory

 

 

is being used).

 

 

 

A05051

18- ENG

Page 18
Image 18