Husky manual ENG A05051

Models: A05051

1 60
Download 60 pages 30.05 Kb
Page 19
Image 19

PROBLEM

CAUSE

CORRECTION

Compressor is

Prolonged excessive use of

Decrease amount of air

not supplying

air.

usage.

enough air to

 

Check the accessory air

operate

Compressor is not large

accessories.

enough for air requirement.

requirement. If it is higher

 

 

than the SCFM or pressure

 

 

supplied by your air

 

 

compressor, you need a

 

 

larger compressor.

 

Hole in hose.

Check and replace if

 

 

required.

 

Air leaks.

Tighten any exposed fittings.

 

 

 

Motor will not

Fuse blown, circuit breaker

Check fuse box for blown

run.

tripped.

fuse and replace as

 

 

necessary. Reset circuit

 

 

breaker. Do not use a fuse or

 

 

circuit breaker with higher

 

 

rating than that specified for

 

 

your particular branch circuit.

 

 

Check for proper fuse. You

 

 

should use a time delay fuse.

 

 

Check for low voltage

 

 

problem.

 

 

Check the extension cord.

 

 

Disconnect the other

 

 

electrical appliances from

 

 

circuit or operate the

 

 

compressor on its own

 

 

branch circuit.

 

Extension cord is wrong

Check the extension cord.

 

length or gauge.

 

 

Loose electrical

Check wiring connection

 

connections.

inside terminal box.

 

Faulty motor.

Have checked by a Trained

 

 

Service Technician.

 

 

 

19- ENG

A05051

Page 19
Image 19
Husky manual ENG A05051