10 Maintenance (machine disconnected)

-Take care to avoid accidental damage.

After some hours of use, carry out a general retightening of all nuts and bolt.

Clean machine after each use.

Lubricate moderately the grease nipples:

-of the rolling bearings (P) [SEE FIG. 8].

-of the cam (Q).

-of the depth adjustment bearing (R).

OIL

Check the engine oil every day. Refer to the engine manual for the replacement schedule. Use:

-SAE 10W30 motor oil with API class MS, SD, SE or better for PETROL engines.

Dispose of the old oil as laid down by the regulations in force.

To empty the motor, place a funnel at the drain outlet (V) [SEE FIG.X9].

Store in a dry place, not accessible to children.

Maintain the tools carefully.

FAULT FINDING

In the event of faulty operation refer to the tables below to find a solution.

• Motor or drum does not rotate

CAUSES

REMEDIES

 

 

Not plugged in

- Make sure that the

properly or cable

supply is correctly

damaged

plugged in (plug,

 

extension lead, etc)

 

- Check the supply

 

cable

No mains voltage

- Test or have tested

 

by an electrician

 

(circuit breaker, plug,

 

etc)

 

 

Motor or drum does not rotate (cont)

CAUSES

REMEDIES

Switch

defective,

- Have tested by an

motor cable damaged

electrician or contact

 

 

the

service

 

 

department

 

Motor

faulty (no

- Contact the service

power,

unpleasant

department to have

smell)

 

the motor replaced

Does not start (petrol

- Engine stopped.

engine)

 

- Faulty or loose spark

 

 

plug.

 

-Refer to engine servicing instructions or contact after sales service.

Belt broken

- Contact

the

parts

 

department

for a

 

replacement.

 

Drum stuck

- Check that the drum

 

rotates,

remove

 

whatever is preventing

 

rotation.

 

 

• Difficult starting

CAUSES

REMEDIES

 

 

English

 

 

 

 

 

 

 

Drum rubs against

-Free the drum to

 

 

ground

make it easier

to

 

 

 

start.

 

 

 

Single phase motor

- Replace the

 

 

 

 

 

 

starting condenser

condenser.

 

 

 

Faulty three phase

- Have it checked by

 

 

supply (2 phases only

an electrician

or

 

 

or motor cable in poor

contact the service

 

 

condition)

department.

 

 

 

 

 

 

 

 

Ineffective operation with jerks and considerable vibration

CAUSES

REMEDIES

- No noticeable work

- Check the setting of

done

the drum (mills)

-Drum at lowest - Change the drum or

position

the cutters, brush,

- Maximum wear

etc . . .

- Abnormal vibration

- Check the rotation of

when grooving or

the cutters on the

milling

four shafts.

- Abnormal cutter

- Change the drum or

wear

the cutters.

23

Page 27
Image 27
Husqvarna CG 200 S manuel dutilisation Oil, Fault Finding