IBM AS/400 manual v IBM 5494 Remote Control Unit User’s Guide, GA27-3852, Prompt, Parameter, Field

Models: AS/400

1 104
Download 104 pages 4.57 Kb
Page 61
Image 61

vIBM 5494 Remote Control Unit User’s Guide, GA27-3852

AS/400

AS/400

 

5494

AS/400

 

 

 

 

 

 

 

Prompt

Parameter

Field

 

Subfield

Value

5494 Value

Notes

 

 

 

 

 

 

 

 

Default

DFTPKTSIZE

5

 

1

64

0

 

packet size

 

 

 

 

 

 

 

 

 

 

 

128

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

256

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

512

3

 

 

 

 

 

 

 

 

 

Local

LCLLOCNAME

H1

 

1

-

-

Values specified for the AS/400

location

 

 

 

 

 

 

CRTCTLRWS command and for the

name

 

 

 

 

 

 

5494 Remote Control Unit must

 

 

 

 

 

 

 

match. This will probably match

 

 

 

 

 

 

 

LCLLOCNAME in the network

 

 

 

 

 

 

 

attributes. This value will probably

 

 

 

 

 

 

 

match the LCLLOCNAME in the

 

 

 

 

 

 

 

network attributes.

 

 

 

 

 

 

 

 

X.25 link

LINKPCL

6

 

2

*QLLC

01

 

protocol

 

 

 

 

 

 

 

 

 

 

 

*ELLC

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Link type

LINKTYPE

AA

 

-

*X25

1

5494 configuration values must

 

 

 

 

 

 

 

match the values specified for the

 

 

 

 

 

 

 

LINKTYPE parameter on the

 

 

 

 

 

 

 

CRTCTLAPPC command. For

 

 

 

 

 

 

 

APPC controllers that specify

 

 

 

 

 

 

 

LINKTYPE(*SDLC), the value

 

 

 

 

 

 

 

specified in the 5494 configuration

 

 

 

 

 

 

 

must be compatible with the

 

 

 

 

 

 

 

physical interface (INTERFACE

 

 

 

 

 

 

 

parameter) specified on the

 

 

 

 

 

 

 

CRTLINSDLC command.

 

 

 

 

 

 

 

Select 1 for communications using

 

 

 

 

 

 

 

X.25 lines.

 

 

 

 

 

 

 

 

X.25

NETLVL

6

 

5

1988

0

Used for X.25 communications only.

network

 

 

 

 

 

 

 

 

 

 

 

1984

1

 

level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1980

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote

RMTCPNAME

13

 

-

-

-

Values specified for the AS/400

control

 

 

 

 

 

 

CRTCTLAPPC command and for

point name

 

 

 

 

 

 

the 5494 Remote Control Unit must

 

 

 

 

 

 

 

match.

 

 

 

 

 

 

 

 

Remote

RMTNETID

11

 

3

-

-

Values specified for the AS/400

network

 

 

 

 

 

 

CRTCTLAPPC and CRTCTLRWS

identifier

 

 

 

 

 

 

commands and for the 5494

 

 

 

 

 

 

 

Remote Control Unit must match.

 

 

 

 

 

 

 

This will probably match LCLNETID

 

 

 

 

 

 

 

in the network attributes and H1:2.

 

 

 

 

 

 

 

 

Remote

RMTLOCNAME

12

 

-

-

-

Values specified for the AS/400

location

 

 

 

 

 

 

CRTCTLRWS command and for the

name

 

 

 

 

 

 

5494 Remote Control Unit must

 

 

 

 

 

 

 

match.

 

 

 

 

 

 

 

 

Chapter 7. Communicating with remote workstation controllers 55

Page 61
Image 61
IBM AS/400 manual v IBM 5494 Remote Control Unit User’s Guide, GA27-3852, Prompt, Parameter, Field, Subfield, Value