The default value for each bit is underlined in the Bit Value column.

To configure the AS/400 to a 3684 retail controller, use the following table.

 

 

AS/400 Parameter and

 

LINECON Bit

Bit Value

Value

Notes

 

 

 

 

0

0

None

Enabled at initial microprogram load (IML). There is no

 

 

 

equivalent parameter for the AS/400 system. Specify 0

 

1

None

to indicate that the controller is enabled at IML, or 1 to

 

 

 

indicate that the controller is not enabled at IML.

 

 

 

 

1

0

NRZI(*NO)

Specifies NRZI data encoding with leading pads (1) or

 

 

 

non-NRZI without leading pads (0).

 

1

NRZI(*YES)

 

 

 

 

 

 

2 and 3

00

SWITCHED (*YES) and

Bit 2: Specify 1 is using nonswitched communications,

 

 

CNN(*SWTPP)

or 0 if using switched communications. If switched, the

 

 

 

SENDID parameter must also be specified.

 

01

Not valid

 

 

 

 

 

Bit 3: Specify 1 if using a multipoint communications

 

10

SWITCHED(*NO) and

 

 

CNN(*NONSWTPP)

protocol, or 0 if not. 01 is not a valid combination for

 

 

 

these bits.

 

11

SWITCHED(*NO) and

 

 

 

 

CNN(*MP)

 

 

 

 

 

4

0

SNBU(*NO)

Switched network backup.

 

 

 

 

 

1

SNBU(*YES)

 

 

 

 

 

5

0

MODEMRATE(*FULL)

Data rate select speed.

 

 

 

 

 

1

MODEMRATE(*HALF)

 

 

 

 

 

6

0

DUPLEX(*HALF)

Data carrier setting.

 

 

 

 

 

1

DUPLEX(*FULL)

 

 

 

 

 

7

0

None

Answer tone generation. There is no equivalent

 

 

 

parameter for the AS/400 system. Specify 0 to indicate

 

1

None

that the controller generates the answer tone, or 1 to

 

 

 

indicate that the answer tone is omitted.

 

 

 

 

Matching AS/400 parameters for 4680/4690 LINE parameter

You must coordinate parameters between the AS/400 and the 4680 or 4690 retail controller. The following table lists those parameters. The 4680 controller requires configuration of the SDLC/SNA LINE parameter.

AS/400 parameters are listed in alphabetical order; the commands on which the parameters are specified are included in the rightmost column of the table.

For more information about configuring the 4680, see the IBM 4680 Store System: Programming Guide.

To configure the AS/400 to a 4680/4690 controller:

vSee “Examples: Connecting AS/400 to a 4690 retail controller” on page 75 for an example of an AS/400 connecting to a 4690 retail controller.

vUse the following table to connect an AS/400 to a 4690 retail controller.

72Version 5

Page 78
Image 78
IBM manual Matching AS/400 parameters for 4680/4690 LINE parameter, Version