IBM v IBM 5494 Remote Control Unit Planning Guide, GA27-3936, Prompt, AS/400 Parameter, Field

Models: AS/400

1 104
Download 104 pages 4.57 Kb
Page 53
Image 53

vIBM 5494 Remote Control Unit Planning Guide, GA27-3936

vIBM 5494 Remote Control Unit User’s Guide, GA27-3852

AS/400

 

 

5494

AS/400

 

 

 

 

 

 

 

Prompt

AS/400 Parameter

Field

Subfield

Value

5494 Value

Notes

 

 

 

 

 

 

 

Local

ADPTADR

H1

5

-

-

Values specified in the AS/400

adapter

 

 

 

 

 

line description (CRTLINTRN

address

 

 

 

 

 

command) and for the 5494

 

 

 

 

 

 

Remote Controller Unit must

 

 

 

 

 

 

match.

 

 

 

 

 

 

 

LAN

ADPTADR

15

-

-

-

Values specified for the AS/400

remote

 

 

 

 

 

CRTCTLAPPC command and

adapter

 

 

 

 

 

for the 5494 Remote Control

address

 

 

 

 

 

Unit must match.

 

 

 

 

 

 

 

Local

LCLLOCNAME

H1

1

-

-

Values specified for the AS/400

location

 

 

 

 

 

CRTCTLRWS command and

name

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match. This will

 

 

 

 

 

 

probably match LCLLOCNAME

 

 

 

 

 

 

in the network attributes. This

 

 

 

 

 

 

value will probably match the

 

 

 

 

 

 

LCLLOCNAME in the network

 

 

 

 

 

 

attributes.

 

 

 

 

 

 

 

Link type

LINKTYPE

AA

-

*LAN

4

5494 configuration values must

 

 

 

 

 

 

match the values specified for

 

 

 

 

 

 

the LINKTYPE parameter on

 

 

 

 

 

 

the CRTCTLAPPC command.

 

 

 

 

 

 

For APPC controllers that

 

 

 

 

 

 

specify LINKTYPE(*SDLC), the

 

 

 

 

 

 

value specified in the 5494

 

 

 

 

 

 

configuration must be

 

 

 

 

 

 

compatible with the physical

 

 

 

 

 

 

interface (INTERFACE

 

 

 

 

 

 

parameter) specified on the

 

 

 

 

 

 

CRTLINSDLC command.

 

 

 

 

 

 

Select 4 for the network

 

 

 

 

 

 

connections.

 

 

 

 

 

 

 

Remote

RMTCPNAME

13

-

-

-

Values specified for the AS/400

control

 

 

 

 

 

CRTCTLAPPC command and

point name

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match.

 

 

 

 

 

 

 

Remote

RMTNETID

11

3

-

-

Values specified for the AS/400

network

 

 

 

 

 

CRTCTLAPPC and

identifier

 

 

 

 

 

CRTCTLRWS commands and

 

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match. This will

 

 

 

 

 

 

probably match LCLNETID in

 

 

 

 

 

 

the network attributes and

 

 

 

 

 

 

H1:2.

 

 

 

 

 

 

 

Remote

RMTLOCNAME

12

-

-

-

Values specified for the AS/400

location

 

 

 

 

 

CRTCTLRWS command and

name

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match.

 

 

 

 

 

 

 

Example: Connecting an AS/400 to a 5494 controller connected by frame relay

Configuration parameters must be coordinated when you connect an AS/400 system to a 5494 controller.

Chapter 7. Communicating with remote workstation controllers 47

Page 53
Image 53
IBM manual v IBM 5494 Remote Control Unit Planning Guide, GA27-3936, Prompt, AS/400 Parameter, Field, Subfield, Value