Matching AS/400 parameters for a 5494 connected by X.21

You must coordinate communications configuration parameters between AS/400 and the 5494 remote controller that is connected by X.21. These parameters are described in the following table. Then the related fields and subfields from the 5494 configuration display are listed next. These values are followed by the AS/400 configuration value and the matching 5494 value to be entered in the display subfield. You can coordinate these values automatically or manually. Pick one of these ways:

vTo automatically connect the AS/400 to a 5494 controller, you can use the automatic remote controller (QAUTORMT) system value.

vTo manually connect the AS/400 to a 5494 controller:

See “Example: Connecting AS/400 to a 5494 controller connected by X.21” on page 53 for an example of connecting AS/400 to a 5494 controller by X.21.

Use the following table to configure the AS/400 to a 5494 controller by X.21.

For more information about configuring the 5494, see these books:

vIBM 5494 Remote Control Unit Planning Guide, GA27-3936

vIBM 5494 Remote Control Unit User’s Guide, GA27-3852,

AS/400

AS/400

 

5494

 

 

 

 

 

 

 

 

Prompt

Parameter

Field

Subfield

AS/400 Value

5494 Value

Notes

 

 

 

 

 

 

 

Connection

CNNNBR

15

-

-

-

Values specified for the AS/400

number

 

 

 

 

 

 

 

 

 

 

 

CRTCTLAPPC command and

 

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match. If the AS/400

 

 

 

 

 

 

CRTCTLAPPC command

 

 

 

 

 

 

specifies CNNNBR(*DC), the

 

 

 

 

 

 

X.21 direct-call user facility

 

 

 

 

 

 

must be used to make the

 

 

 

 

 

 

connection.

 

 

 

 

 

 

 

Local

LCLLOCNAME

H1

1

-

-

Values specified for the AS/400

location

 

 

 

 

 

CRTCTLRWS command and

name

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match. This will

 

 

 

 

 

 

probably match LCLLOCNAME

 

 

 

 

 

 

in the network attributes. This

 

 

 

 

 

 

value will probably match the

 

 

 

 

 

 

LCLLOCNAME in the network

 

 

 

 

 

 

attributes.

 

 

 

 

 

 

 

Remote

RMTCPNAME

13

-

-

-

Values specified for the AS/400

control

 

 

 

 

 

CRTCTLAPPC command and

point name

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match.

 

 

 

 

 

 

 

Remote

RMTNETID

11

3

-

-

Values specified for the AS/400

network

 

 

 

 

 

CRTCTLAPPC and

identifier

 

 

 

 

 

CRTCTLRWS commands and

 

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match. This will

 

 

 

 

 

 

probably match LCLNETID in

 

 

 

 

 

 

the network attributes and H1:2.

 

 

 

 

 

 

 

Remote

RMTLOCNAME

12

-

-

-

Values specified for the AS/400

location

 

 

 

 

 

CRTCTLRWS command and

name

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match.

 

 

 

 

 

 

 

52Version 5

Page 58
Image 58
IBM manual Matching AS/400 parameters for a 5494 connected by, v IBM 5494 Remote Control Unit Planning Guide, GA27-3936