Image 42
36Version 5

 

AS/400

Remote AS/400

 

AS/400 Prompt

Parameter

Parameter

Notes

 

 

 

 

Exchange identifier

EXCHID

EXCHID

If used, the local AS/400 controller description EXCHID

 

 

 

must match the remote AS/400 line description

 

 

 

EXCHID. The first three digits of the exchange identifier,

 

 

 

known as the block number, is 056 for the AS/400 line.

 

 

 

You can use the WRKLIND command to determine this

 

 

 

value.

 

 

 

 

Initial connection

INLCNN

INLCNN

Values specified for each system must be coordinated;

 

 

 

INLCNN(*ANS) must not be specified for both systems.

 

 

 

 

Link protocol

LINKPCL

LINKPCL

For X.25 connections, values specified for each system

 

 

 

must match; both must be *QLLC or *ELLC.

 

 

 

 

Remote control point

RMTCPNAME

LCLCPNAME

RMTCPNAME specified on the local AS/400 system

name

 

 

controller description must match the local control point

 

 

 

name specified in the network attributes of the remote

 

 

 

AS/400 system.

 

 

 

 

Remote network

RMTNETID

LCLNETID

RMTNETID specified on the local AS/400 system

identifier

 

 

controller description must match the local network ID

 

 

 

specified in the network attributes of the remote AS/400

 

 

 

system.

 

 

 

 

Data link role

ROLE

ROLE

The value specified for the local AS/400 controller

 

 

 

description ROLE parameter must match the remote

 

 

 

AS/400 line description ROLE value.

 

 

 

 

X.25 reverse charging

RVSCRG

RVSCRG

Values specified for each system must be coordinated.

 

 

 

 

Switched network

SNBU

SNBU

Values specified for each system must match.

backup

 

 

 

 

 

 

 

Source service access

SSAP

DSAP

SSAP specified for the local AS/400 system must match

point

 

 

the DSAP specified in the remote AS/400 controller

 

 

 

description.

 

 

 

 

Station address

STNADR

STNADR

Values specified for each system must match, unless

 

 

 

both controller descriptions specify ROLE(*NEG).

 

 

 

 

Note: For asynchronous controllers (CRTCTLASC command), if the remote system controller description specifies RMTVFY(*YES), the local system controller description must specify a local identifier (LCLID parameter) and local location name (LCLLOCNAME parameter). The remote system must also create a configuration list with the LCLID and LCLLOCNAME values from the local system controller description.

For more information on AS/400 parameters, see the Communications ConfigurationManual background book.

Matching AS/400 device description parameters for a remote AS/400 system

You must coordinate communications configuration parameters between local and remote AS/400 systems. The parameters are described in the following table. This table shows those prompts and parameters that must be coordinated when you specify device descriptions for the local and remote AS/400 systems.

To configure a local AS/400 to a remote AS/400:

vSee “Connecting one AS/400 to another AS/400 system” on page 37 for an example of connecting one AS/400 to another AS/400 system.

vUse the following table for the device description.