Displaying the Detector control screen
To display the control screen that you can use to run the Detector at a CICS
terminal, ®rst type the transaction identi®er CAFF, then press Enter. In response, the Detector control screen, CAFF01 (shown in Figure 6), is displayed. You can use this screen to review and change the state of the Detector, or to display the Detector options screen, CAFF02 (shown in Figure 7 on page 36).
To refresh the values displayed on the screen at any time, press Enter.
To leave the Detector control screen, press the F3 (or F12) function key. This does not affect the state of the Detector.
CAFF01 | CICS Transaction | Affinities Utility | Applid CICSPDN1 | |||
Press | Start key (F5) | to start detection. „1… |
| |||
Press | Options key (F4) | to modify the CAFF operation options. |
| |||
Press | Enter to update statistics. |
|
| |||
CAFF state . . . . . . . . : STOPPED by user <userid> „2… |
| |||||
Number of pauses . . . . . : | 0 | „3… |
| |||
Number of saves. . . . . . : | 6 | „3… |
| |||
Records written last save. : | 257 | „4… |
| |||
Total records on file. . . : | 834 | „5… |
| |||
Date/time of last start. . : | 11/24/95 09:05:23 (MM/DD/YY HH:MM:SS) „6… | |||||
Date/time of last save . . : | 11/24/95 11:13:12 (MM/DD/YY HH:MM:SS) | |||||
Date/time of last change . : | 11/24/95 11:12:34 (MM/DD/YY HH:MM:SS) | |||||
Total time RUNNING . . . . : | 0002:08:12 (HHHH:MM:SS) „7… |
| ||||
Total time PAUSED. . . . . : | 0000:00:00 (HHHH:MM:SS) |
| ||||
Table dataspace name . . . : |
| % full „8… |
| |||
„9… |
|
|
|
|
|
|
F1=Help F3=Exit F4=Options F5=Start F6=Stop F7=Pause F8=Continue F12=Cancel „10… |
| Figure 6. Detector control screen, CAFF01 |
| The Detector control screen, CAFF01, shows the following: |
| „1… The functions that you can select from this state of the Detector. For any state |
| of the Detector, only appropriate functions are displayed. |
| „2… The current state of the Detector. If the state is STOPPED, the display shows |
| the reason why it was stopped. |
| Notes: |
| 1. When you stop the Detector, the CAFF state changes to STOPPED only after |
| the Detector has saved the affinity data. |
| 2. When you pause the Detector, the CAFF state changes to PAUSED before the |
| Detector saves the affinity data (to ensure that the Detector pauses |
| immediately). After the state has changed to PAUSED, you can refresh the data |
| displayed by pressing Enter. |
| „3… The number of times that the Detector has been paused, and the number of |
| times data has been saved, since the last time that it was started. |
„4… The number of new records and updates to existing records written to the | |
affinity data VSAM ®les when data was last saved. |
32 CICS Transaction Affinities Utility Guide