IBM OS manual Changing the Detector options

Models: OS

1 103
Download 103 pages 52.71 Kb
Page 52
Image 52
Changing the Detector options

Note: If there are a large number of data records to be saved, the CAFF screen may be frozen for some appreciable time, until the records have been saved.

You may want to stop the Detector when it has detected all affinities. This is indicated by the ªDate/time of last changeº ®eld changing very infrequently and, if the optional periodic saves are performed, the ªRecords written last saveº ®eld being consistently near zero.

If CICS shuts down normally, but the Detector is not stopped, the Detector eventually detects that CICS is not running and terminates cleanly with a save.

Changing the Detector options

You can control how the Detector operates by changing the options that it uses. Option values are preserved in the Transaction Affinities Utility control ®le, CAUCNTL, so that they can be used across separate runs of the Detector. For more information about the control ®le, see ªThe control record VSAM ®leº on page 17.

Notes:

1.Generally, any option can be changed while the Detector is stopped. However, some options can also be changed while the Detector is paused or running. (These options are identi®ed in the descriptions on page 37.)

2.You can change an option even if the Detector is stopped and the Reporter is running (that is, reading the CAUCNTL ®le).

To review and change the options that the Detector uses, press the F4 function key of the Detector control screen, CAFF01. In response, the Detector displays its options screen, CAFF02 (shown in Figure 7) is displayed.

To update the options screen, press Enter.

To return to the Detector control screen, press the F12 function key.

CAFF02

CAFF Operation Options

 

Applid CICSPDN1

Modify the options and press Enter to update, or press Cancel (F12)

 

Control options

„1…

 

 

 

 

 

Perform periodic saves

. . . . . .

Y

(Y=Yes or N=No)

 

Restore data on start.

. . . . . .

N

(Y=Yes or N=No)

 

Multiple signon with same userid . N

(Y=Yes or N=No)

 

Size of dataspace. . .

. . . . . .

16

(10

to 2000 MB)

 

Transid prefix (optional)

___

(1 to 3 characters)

 

Detect affinity types (Y=Yes or N=No)

„2…

 

 

 

Inter-transaction

Transaction-system

 

Transaction-system

Y „3…

ENQ, DEQ . . .

. Y

INQUIRE, SET

. .

. Y

WAIT

TS Queue . . .

. Y

ENABLE, DISABLE.

. Y

DISCARD

Y

ADDRESS CWA. .

. Y

EXTRACT. . .

. .

. Y

CREATE

Y

RETRIEVE WAIT.

. Y

COLLECT STATS. .

. Y

 

 

LOAD

. Y

PERFORM. . .

. .

. Y

 

 

GETMAIN SHARED . Y

RESYNC . . .

. .

. Y

 

 

CANCEL . . . .

. Y

 

 

 

„4…

 

Last updated by <userid>

on 11/24/95 09:04:35

 

F1=Help „5…

 

 

 

 

 

 

F12=Cancel

Figure 7. Detector options screen

36 CICS Transaction Affinities Utility Guide

Page 52
Image 52
IBM OS manual Changing the Detector options