Pausing the collection of affinity data

Each time the Detector is started, a new data space is created. For help with calculating the likely data space storage requirement, see ªEstimating the size of the MVS data space and VSAM ®lesº on page 21. You specify this size on the Detector options screen, CAFF02. You can also specify that data from affinity data VSAM ®les (for example, from previous Transaction Affinities Utility runs) is to be loaded into the data space when it is created. For more information about the CAFF02 options screen, see ªChanging the Detector optionsº on page 36.

Note: If there are a large number of data records to be loaded into the data space when it is created (for example, from previous Transaction Affinities Utility runs), the CAFF screen may be frozen for some appreciable time, until the records have been loaded.

Pausing the collection of affinity data

When you can pause affinity data collection

You can pause the collection of affinity data only when the Detector is currently running.

To pause the collection of affinity data, use one of the methods shown in Table 4.

Table 4. Methods for pausing data collection by the Detector

Where used

Command or function key

 

 

Control display, CAFF01

F7 function key

 

 

3270 terminal

CAFF PAUSE

 

 

Console

F cicsjob, CAFF PAUSE „1…

 

 

Application program

EXEC CICS START TRANSID('CAFF') FROM('PAUSE')

 

 

Note:

„1… cicsjob is the name of your CICS startup job.

Using one of the methods listed in Table 4 causes the Detector to stop collecting data until you are ready to resume. The data already collected remains in the data space, and can be saved to the affinity data VSAM ®les when the Detector is paused. (You can specify that data be saved when the Detector is paused on the CAFF02 options screen, as described in ªChanging the Detector optionsº on page 36.)

Resuming the collection of affinity data

When you can resume collecting affinity data

You can resume collecting affinity data only when the Detector is currently paused.

To resume collecting affinity data, use one of the methods shown in Table 5 on page 35.

34 CICS Transaction Affinities Utility Guide

Page 50
Image 50