Note: Power consumption and heat output vary depending on the number and type of optional features installed and the power-management optional features in use.

Heat output

Approximate heat output in British thermal units (Btu) per hour:

Minimum configuration: 256 Btu/hr (75 watts)

Maximum configuration: 706 Btu/hr (207 watts)

Airflow

Approximately 0.5 cubic meter per minute (18 cubic feet per minute)

Acoustical noise-emission values

Average sound-pressure levels:

At operator position:

Idle: 33 dBA

Operating: 39 dBA

At bystander position-1 meter (3.3 ft):

Idle: 4.4 bels

Operating: 4.9 bels

Note: These levels were measures in controlled acoustical environments according to procedures specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779, and are reported in accordance with ISO 9296. Actual sound-pressure levels in your location might exceed the average values stated because of room reflections and other nearby noise sources. The declared sound power levels indicate an upper limit, below which a large number of computers will operate.

PC300 PL and GL tower

Dimensions

Height: 378 mm (14.9 in.)

Width: 192 mm (7.6 in.)

Depth: 383 mm (15.1 in.)

Weight

Minimum configuration as shipped: 8.3 kg (18.3 lb)

Maximum configuration: 10.2 kg (22.5 lb)

Environment

Air temperature:

System on: 10° to 35°C (50° to 95° F)

System off: 10° to 43°C (50° to 110° F)

Humidity

System on: 8% to 80%

System off: 8% to 80%

Maximum altitude: 2134 m (7000 ft), the maximum altitude at which the specified air temperatures apply. At higher altitudes, the maximum air temperatures are lower than those specified.

Electrical input

Input voltage:

— Low range:

22PC 300 GL and 300 PL