CHAPTER 3 STARTING AND STOPPING
User's Manual U13502EJ2V0UM00 35
In the TYPE setting dialog box, device-specific information is automatically set when the parameter file has been
loaded, and the text box is grayed out. The parameters that can be changed by the user in this dialog box are as
follows:
1. COMM PORT
Selects the communication mode with the target. The communication modes that can be selected depend
on the device. For details, refer to the manual for the device.
The communication rate can be also changed. The communication rate also depends on the function and
the device operating clock. For details, refer to the manual for the device.
2. ROM TYPE
Usually, only FLASH is set. If the device used has an on-chip EEPROMTM, however, the internal data of the
EEPROM can be read to the PG-FP3 by selecting EEPROM.
3. CPU CLOCK
Selects the CPU operating clock. When the FA adapter is used, select In Flashpro to choose a clock from
Flashpro Clock. When the user target board is used, select On target board and enter the clock frequency
of the target board in the text box.
Some devices have a multiply circuit. In this case, enter a multiple for Multiple Rate.
Voltage setting
Set the operating voltage of the target. When the [Setting..Voltage] command is executed, the following dialog
box opens.
This dialog box is used to set the operating voltage of the target and the VPP voltage. If the parameter file has
been loaded, the default voltages are set automatically. Because some devices allow you to select an operating
voltage, set the voltage according to target conditions.