CHAPTER 5 COMMAND REFERENCE
User's Manual U13502EJ2V0UM00 53
Selecting a transmission clock frequency from the PG-FP3 (Flashpro clock)
If [In Flashpro] has been selected when a CPU clock source is being entered, select the clock the PG-FP3
transmits from the frequencies listed below. Different devices provide different operating frequency ranges for
the target microcontroller. Select the correct frequency by referring to the manual for the device.
16.0 MHz
8.0 MHz
4.0 MHz
2.0 MHz
Caution When the set frequency is changed, execute the [Other-Status] command to check the
contents displayed in the log window.
Setting a multiple for the operating clock (Multiple Rate)
If the target has a multiplier circuit and operation will be performed in multiple mode, enter a multiple. Usually,
this parameter is set to 01.00. To operate in multiple mode, enter a multiple.
Example To operate in ×5 mode Enter 05.00.
BLOCK range setting
In block mode, set a range of blocks. In this mode, the [Block/Area] button at the right of the TYPE setting
screen becomes active. When this button is clicked, the dialog box shown below opens. Enter the block range
to be used and click the [OK] button. The block range will be set.
Block: Number of device blocks
(automatically set)
Block Number: Selected blocks
(set by user)
For example, if the block range is specified as 0 to 2 for erasure, Block 0, Block 1, and Block 2 are erased. To
specify only one block, enter the same value as the start block and end block.
Caution To set a block, you must set BLOCK mode by clicking the CHIP/BLOCK/AREA button in the
FLASHPRO3 window or by executing [set block].
For information on changing the mode, see Section 5.3.6.