CHAPTER 5 COMMAND REFERENCE
User's Manual U13502EJ2V0UM00 55
5.2.4 Option
[Option] sets detailed conditions for each device, such as erase time, write time, and convergence time. These
conditions are set to the default values when the parameter file is loaded. Unless otherwise specified, use the default
values. If incorrect values are specified, the service life of the device may be shortened or the device may be
damaged.
Click [Options...] on the [Setting] pull-down menu. The dialog box below will open. Change the parameter setting in
this dialog box and click the [OK] button. The setting will be changed .
Erase time: Sets the erase time for the device.
If 0 second is set, erasure processing is not performed.
Write time: Sets the write time for the device.
Convergence time: Sets the time of the function that prevents excessive erasing of the device.
5.2.5 Reset
[Reset] restarts the PG-FP3 system. The PG-FP3 must be restarted if you want to check the firmware version, or if
the system has failed.
Execute this command by selecting [Reset] from the [Setting] pull-down menu. If the PG-FP3 is restarted correctly,
an LED on the PG-FP3 blinks and then LEDs Erase, Program, and Verify light. The firmware version is then displayed
in the log window at the lower left of the screen.