CHAPTER 5 COMMAND REFERENCE
User's Manual U13502EJ2V0UM00 51
Entering the end address (END ADDRESS)
The end address is determined by the parameter definition information. It is automatically set in the Block and
Area modes.
Remark The end address range that can be specified with the PG-FP3 is 2 Mbytes (1FFFFFH). This is a
hardware specification.
Selective input of serial port (COMM PORT)
Select the mode of communication between the PG-FP3 and target device from the modes listed below.
Some of the following communication modes cannot be used with some devices. Select one of the
communication modes listed in the manual for the device. The channel number of some devices starts with ch-
1. In this case, ch-0 is equivalent to ch-1 of the device.
Parameter on screen Description
SIO ch-0 SIO (3-wire clocked communication port) channel 0
SIO ch-1 SIO (3-wire clocked communication port) channel 1
SIO ch-2 SIO (3-wire clocked communication port) channel 2
SIO ch-3 + handshake SIO (3-wire clocked communication port with handshaking)
I2C ch-0 I2C channel 0
I2C ch-1 I2C channel 1
I2C ch-2 I2C channel 2
I2C ch-3 I2C channel 3
UART ch-0 (Async.) UART (asynchronous communication port) channel 0
UART ch-1 (Async.) UART (asynchronous communication port) channel 1
UART ch-2 (Async.) UART (asynchronous communication port) channel 2
UART ch-3 (Async.) UART (asynchronous communication port) channel 3
Port A (Pseudo-3 wired) Port (pseudo 3-wire) A
Port B (Pseudo-3 wired) Port (pseudo 3-wire) B
Port C (Pseudo-3 wired) Port (pseudo 3-wire) C
Entering a communication rate for the UART (UART BPS)
Select a communication rate from the following if UART is selected for the serial port.
4800 bps
9600 bps
19200 bps
31250 bps
38400 bps
76800 bps
Caution If the target CPU clock is slow, use a slow communication rate. If the communication rate is
too fast, communication may not be performed correctly (for details, refer to the target device
specifications).