Image 112

FRU

Applicable test

 

 

TrackPont or Pointing

If the TrackPoint does not work, see if an

device

external PS/2 mouse is connected to the

 

mouse/keyboard connector and remove

 

it. The TrackPoint is automatically

 

disabled if an external PS/2 mouse is

 

attached. Check also if the TrackPoint

 

driver is correctly installed by accessing

 

Windows Device Manager via the System

 

icon in the Control Panel.

 

After you use the TrackPoint, the pointer

 

drifts on the screen for a short time. This

 

self-acting pointer movement can occur

 

when a slight, steady pressure is applied

 

to the TrackPoint pointer. This symptom

 

is not a hardware problem. No service

 

actions are necessary if the pointer

 

movement stops in a short period of time.

 

If this does not correct the TrackPoint

 

problem, continue with the following:

 

Mouse (Interactive Tests).

 

 

Hard disk drive

Fixed Disks (Diagnostics)

 

 

CD-ROM drive

CD-ROM, DVD, CD-RW, DVD/CD-RW

 

(Interactive Tests)

 

 

Memory

1. If a DIMM is installed, remove it and

 

 

run Memory Test-Quick (Diagnostics)

 

2. If the problem does not recur, replace

 

the DIMM and run the test again.

 

3. If the test does not detect the error,

 

run Memory Test-Full (Diagnostics)

 

 

Fan

1. Power on system and check the air

 

 

turbulence at the louver at the rear of

 

the computer.

 

2. Run the fan test in Other Devices

 

(Diagnostics).

 

 

106ThinkPad R30/R31 HMM