Symptom-to-FRU Index
The
Note: Perform the FRU replacement or actions in the sequence shown in the FRU/Action columns. If a FRU does not solve the problem, put the original part back in the computer. Do not replace a
This index can also be used to help you decide which FRUs should be available when servicing a computer.
Numeric error codes show the errors detected in POST or system operation (runtime). In the following error codes, X can be any number.
If no codes are available, use narrative symptoms.
If the symptom, is not listed, go to “Undetermined Problems” on page 49.
Note: For any IBM device not supported by the diagnostic codes in this ThinkPad computer, see the manual for that device.
Numeric Error Codes and Messages
Error | Message | Meanings | Comment |
Code |
|
|
|
|
|
|
|
0200 | Failure Fixed | Fixed disk is not | Check whether |
| Disk | working or not | fixed disk is |
|
| configured | attached |
|
| properly. Check | properly (e.g. |
|
| to see if fixed | cable, jumper, |
|
| disk is attached | power,..). Enter |
|
| properly. Run | Setup to check if |
|
| setup. Find out if | the fixed disk |
|
| the | type is correctly |
|
| type is correctly | identified. |
|
| identified. |
|
|
|
|
|
010 | Memory Error | Extended | Change memory |
| at mmmm: | memory not | module. |
| nnnn | working or not |
|
|
| configured |
|
|
| properly at offset |
|
|
| nnnn, |
|
|
|
|
|