IBM RS/6000 SP manual Step, Switch description and problem determination MAP

Models: RS/6000 SP

1 114
Download 114 pages 42.66 Kb
Page 23
Image 23
Step 0590-001

Switch description and problem determination (MAP 0590)

There are two LEDs on the front of each SP Switch. For quick reference, their definitions are as follows:

Environment (Yellow)

Off No environmental problems detected by switch supervisor card.

On Warning of environmental condition out of nominal range. Preventative Maintenance should be scheduled for this switch.

Flashing

Serious environmental condition detected; power shut off.

Power (Green)

Off No 48 V dc power available at the SP Switch.

Flashing

Power available at the SP Switch, but switch logic is Off.

On Power available at the SP Switch, and logic is On.

Note: Refer to ªService position proceduresº on page 3-9 for placing or removing the SP Switch into or from service position.

Step 0590-001

Read the following warning and then follow steps to ensure continuity of customer's jobs in the queue.

Attention: Servicing a processor node or SP Switch will interrupt customer usage of the processor node and the remainder of the switch network. If the switch feature must be replaced in a multi-frame system, refer to ªRemoving and restoring switch resourcesº on page 3-7, for information on isolating the SP Switch.

Attention: It is possible that the customer has modified switch cabling from standard configurations; therefore, be careful about relying on node and frame information. Any connector jack numbers will be correct regardless of the customer's cable configuration, so you may trace the cabling from the jack number if necessary.

1.Have customer complete all active parallel jobs or jobs using switch interface (for example, tape B/U ADSM), then remove the switch feature from the active configuration. Refer to ªRemoving and restoring switch resourcesº on page 3-7,for these procedures.

2.Check for system monitor errors indicating environmental problems with the switch feature. These can be viewed by issuing the appropriate command from the control workstation:

v errpt -a-N sphwlog pg (For SSP code levels 1.02 and higher)

vRefer to the Starting a service call (MAP 0100)in RS/6000 SP: System Service Guide for more information on the pg command

Note: In a frame with processor nodes, entries for the switch will refer to ªnode17º or ªslot17º. In a multi-switch frame, switches will be listed as even slot addresses.

3.Determine the SP Switch type (see page 1-1)

4.Refer to Table 1-1 on page 1-4for a prioritized list of conditions. Find the first condition that describes your problem, then perform the associated action.

Chapter 1. Maintenance Analysis Procedures (MAPs) 1-3

Page 23
Image 23