Replacing the switch supervisor card
1. Position and hold the switch supervisor card at the far end of the hot-plug actuator.
2. Insert the far end of the actuator into the actuator guides of switch slot J2.
3. Push the actuator to the end of the guide track.
4. Push the actuator handle inward and seat the supervisor card into switch planar jack J2.
5. Hook the card retention bracket to the chassis side-wall mount and swing the bracket closed.
vMake certain all actuator handles are inside the bracket.
6. Secure the card retention bracket to the switch chassis by tightening the captive screw.
7. Reconnect the switch supervisor cable to the switch supervisor card.
8. Perform “Updating the SP Switch2 supervisor code” on page3-8.
9. Return to the procedure that directed you here.
Removing an interposer card
Note: An interposer card may be either a:
vSwitch interposer
vBlank interposer
Note: Interposer card assemblies are hot-pluggable.
Figure 4-5. Installing an SPSwitch2 supervisor and interposer cards
SP Switch2 service procedures
4-6 RS/6000 SP: SP Switch2 Service Guide