Chapter 1 Product Overview
Switching Modules
Send documentation comments to mdsfeedback-doc@cisco.com.
The supervisor module can force a reset on the switching module and controls whether power is applied to the switching module.
If a single component or a set of components on the switching module fails, this does not disable other switching modules if that is the only failure in the system.
For the detection of most component failures, each switching module has a hardware watchdog timer that resets the card if is not serviced periodically.
Switching Module LEDs
Table
Table
Modules
LED | Status | Description |
|
|
|
Status | Green | All diagnostics pass. The module is operational (normal |
|
| initialization sequence). |
|
|
|
| Orange | The module is booting or running diagnostics (normal |
|
| initialization sequence). |
|
| An over temperature condition occurred (a minor |
|
| threshold was exceeded during environmental |
|
| monitoring). |
|
|
|
| Red | The diagnostic test failed. The module is not operational |
|
| because a fault occurred during the initialization |
|
| sequence. |
|
| An over temperature condition occurred (a major |
|
| threshold was exceeded during environmental |
|
| monitoring). |
|
|
|
Speed | On | 2 Gbps mode. |
|
|
|
| Off | 1 Gbps mode. |
|
|
|
|
| Cisco MDS 9216 Switch Hardware Installation Guide |
|
|
|
|
| ||
|
|
| ||
|
|
|