Chapter 1 Product Overview

Interface Module

Send documentation comments to mdsfeedback-doc@cisco.com.

Interface Module LEDs

Table 1-2describes the LEDs provided on the Cisco MDS 9216 interface module.

Table 1-2 LEDs on the Cisco MDS 9216 Interface Module

 

 

LED

Status

Description

 

 

 

 

 

 

 

Status

Green

All diagnostics pass. The module is operational

 

 

 

 

(normal initialization sequence).

 

 

 

 

 

 

 

 

Orange

The module is booting or running diagnostics

 

 

 

 

(normal initialization sequence).

 

 

 

 

An over temperature condition occurred (a minor

 

 

 

 

threshold was exceeded during environmental

 

 

 

 

monitoring).

 

 

 

 

 

 

 

 

Red

The diagnostic test failed. The module is not

 

 

 

 

operational because a fault occurred during the

 

 

 

 

initialization sequence.

 

 

 

 

An over temperature condition occurred (a major

 

 

 

 

threshold was exceeded during environmental

 

 

 

 

monitoring).

 

 

 

 

 

 

 

System

Green

All chassis environmental monitors are reporting OK.

 

 

 

 

 

 

 

 

Orange

The power supply failed or the power supply fan

 

 

 

 

failed.

 

 

 

 

Incompatible power supplies are installed.

 

 

 

 

The redundant clock failed.

 

 

 

 

 

 

 

 

Red

The temperature of the supervisor module major

 

 

 

 

threshold was exceeded.

 

 

 

 

 

 

 

MGMT 10/100

Green

Link is up.

 

 

Ethernet Link

 

 

 

 

 

 

Off

No link.

 

 

LED

 

 

 

 

 

 

 

 

 

 

 

 

 

MGMT 10/100

Green

Traffic is flowing through port.

 

 

Ethernet

 

 

 

 

 

 

Off

No link or no traffic.

 

 

Activity LED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 