Send documentation comments to mdsfeedback-doc@cisco.com.
1-9
Cisco MDS 9216 Switch Hardware Installation Guide
78-16165-01
Chapter1 Product Overview
Interface Module
Interface Module LEDs
Table 1 -2 describes the LEDs provided on the Cisco MDS 9216 interface module.
Table1-2 LEDs on the Cisco MDS 9216 Interface Module
LED Status Description
Status Green All diagnostics pass. The module is operational
(normal initialization sequence).
Orange The module is booting or running diagnostics
(normal initialization sequence).
An over temperature condition occurred (a minor
threshold was exceeded during environmental
monitoring).
Red The diagnostic test failed. The module is not
operational because a fault occurred during the
initialization sequence.
An over temperature condition occurred (a major
threshold was exceeded during environmental
monitoring).
System Green All chassis environmental monitors are reporting OK.
Orange The power supply failed or the power supply fan
failed.
Incompatible power supplies are installed.
The redundant clock failed.
Red The temperature of the supervisor module major
threshold was exceeded.
MGMT 10/100
Ethernet Link
LED
Green Link is up.
Off No link.
MGMT 10/100
Ethernet
Activity LED
Green Traffic is flowing through port.
Off No link or no traffic.