Send documentation comments to mdsfeedback-doc@cisco.com.
B-5
Cisco MDS 9216 Switch Hardware Installation Guide
78-16165-01
AppendixB Technical Specifications
Power Specifications
Table B -6 provides a sample calculation of power and heat dissipation for the
following hardware configuration at maximum wattage:
Cisco MDS 9216 chassis, including two 845 WattAC power supplies
Fixed supervisor module, with 16 Fibre Channel ports
One 32-port Fibre Channel switching module.
TableB-5 Power Requirements and Heat Dissipation for the 845 Watt Power Supply
Module Type /
Product Number
Power
Required
(Watts)
Heat
Dissipation
(BTU/hr)
Input Current
90 VAC
(amps)
120 VAC
(amps)
180 VAC
(amps)
240 VAC
(amps)
Cisco MDS 9216
chassis with fan module
DS-C9216-K9
38 164 (.799) 0.53 0.40 0.27 0.20
Fixed supervisor
module (16-port FC
module, 1Gbps/2Gbps)
220 940 (.799) 3.05 2.29 1.53 1.15
16-port FC module,
1Gbps/2Gbps
DS-X9016
220 940 (.799) 3.05 2.29 1.53 1.15
32-port FC module,
1Gbps/2Gbps
DS-X9032
200 855 (.798) 2.78 2.08 1.39 1.04
8-port IPS module
DS-X9308- SMIP 220 940 (.799) 3.05 2.29 1.53 1.15
32-port ASM module,
DS-X9032-SMV 295 1 260 4.10 3.07 2.05 1.54