Appendix B Technical Specifications

Supported Power Supply Plugs

Send documentation comments to mdsfeedback-doc@cisco.com.

Table B-6 Sample Calculation for Power and Heat Dissipation

 

 

Power

Heat

Input Current

 

 

 

 

 

 

 

 

Module Type /

 

Required

Dissipation

90 VAC

120 VAC

180 VAC

240 VAC

Product Number

Qty

(Watts)

(BTU/hr.)

(amps)

(amps)

(amps)

(amps)

 

 

 

 

 

 

 

 

Cisco MDS 9216

1

38

164

0.53

0.40

0.27

0.20

chassis with fan module

 

 

 

 

 

 

 

DS-C9216-K9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fixed supervisor

1

220

940

3.05

2.29

1.53

1.15

module (16-port FC

 

 

 

 

 

 

 

module, 1Gbps/2Gbps)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32-port FC module,

1

200

855

2.78

2.08

1.39

1.04

1Gbps/2Gbps

 

 

 

 

 

 

 

DS-X9032

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total

 

458

1959

6.36

4.77

3.19

2.39

 

 

 

 

 

 

 

 

Supported Power Supply Plugs

A separate power cord is provided for each power supply. The power cords have an IEC C15 connector on the end that plugs into the switch.

Note Only the power cords provided with the switch are supported.

Figure B-1shows the supported power supply plugs for the Cisco MDS 9216 Switch.

 

Cisco MDS 9216 Switch Hardware Installation Guide

B-6

78-16165-01

Page 110
Image 110
Cisco Systems 9216 manual Supported Power Supply Plugs