GEM0650/0956/1256 Remote

For the Installer

Final Check List

___1. Is the ice system installed indoors in a location where air and water temperatures are controlled, and where they do not exceed the design limitations?

___2. Is there an electrical service within sight of the installed machine? Has the voltage been checked, and compared to nameplate requirements?

___3. Have all the plumbing connections been made and checked for leaks?

___4. Has the machine and bin been leveled?

___5. Is there a minimum of 6 inches clearance at the rear, left and right of the machine for proper service access?

___6. Is the water pressure a minimum of 20 psig?

___7. Has the machine been secured to the bin or dispenser?

___8. Is there a water shut off valve installed near the machine?

___9. Is the remote condenser installed per local codes, and in a place where it has adequate ventilation and minimal solar heat gain?

___10. Has all shipping material and literature (inside front panel) been removed from the units?

___11.Have the remote condenser and pre-charged lines been properly installed?

Condenser Leveled?

Roof Holes Sealed?

Remote condenser

 

Machine Leveled?

secured?

 

 

 

 

 

Plumbing?

Power Supply?

___12. Has the electrical connection between the ice maker and condenser been made?

___13. Verify that the master switch is in the OFF position.

___14. Switch ON the electrical power.

___15. Refer to the Pre-Start instructions, Page 15

Page 14

Page 20
Image 20
Ice-O-Matic GEM0650R, GEM1256R, GEM0956R installation manual Final Check List