GEM0650/0956/1256 Remote

Operation: Performance

Typical Low Side Pressure:

 

Remote:

34-38 PSIG

Typical Discharge Pressure:

 

Remote:

220-275 PSIG

Typical Compressor Amp Draw:

 

GEM0650 115/60/1

8-9 Amps

GEM0956 208-230/60/1

4-5 Amps

GEM1256 208-230/60/1

5-6 Amps

Typical Auger Drive Motor Amp Draw:

 

GEM0650 115/60/1

3.1 to 3.5 Amps

GEM0956 208-230/60/1

1.6 to 1.8 Amps

GEM1256 208-230/60/1

1.6 to 1.8 Amps

Expansion Valve Superheat:

6-8 degrees

High Pressure Cut Out- Automatic Reset:

450 PSIG

Pump Down Cut Out- Automatic Reset:

15 PSIG

Refrigerant Charge: R404A

 

GEM0650 Remote

208 ounces

GEM0956 Remote

208 ounces

GEM1256 Remote

208 ounces