| IOD16022 |
Service Diagnosis/Electrical Sequence | IOD22030 |
Service Diagnosis |
|
PROBLEM | PROBABLE CAUSE |
Will not dispense | No ice in hopper |
ice | Vend switch does not close |
| |
| Drive motor not working |
| Door solenoid will not open door |
| Rotor will not turn |
| Relay for vend switch does not |
| close during operation |
CORRECTION
Fill bin with ice
Check vend switch, replace if open Check drive motor, replace if not working Check/replace door and solenoid Check hub of rotor
Check relays, replace as required
Electrical Sequence Reference Wiring Diagram, Page
Ice Vending
Ice is dispensed as long as the vend lever or push button is depressed or until the bin is empty.
When the ice vend lever or push button is depressed, the vend switch closes, and makes a circuit to the coil of relay A.
When relay A is energized, relay A’s contacts
When relays A’s contacts
When relay B’s coil is energized, it closes a circuit to the gearmotor, and the gearmotor turns the rotor.
Agitation
Relay A’s contacts
The timer is energized when the unit is not dispensing. The timer switch will close for a few seconds every two hours.
When the timer switch is closed, it makes a circuit to relay B’s coil.
When relay B is energized, it powers the gearmotor and the rotor is turned.
Page 10