SECTION 5 ADJUSTMENT PROCEDURES

5-1 PREPARATION

When adjusting the contents on page 5-9, a JIG CABLE (see illustration as below) is required.

Some adjustments must be performed on the “ADJUSTMENT MODE”. Entering the “ADJUSTMENT MODE”, refer to the next page in detail.

REQUIRED TEST EQUIPMENT

 

 

 

 

 

 

 

 

 

EQUIPMENT

 

GRADE AND RANGE

EQUIPMENT

GRADE AND RANGE

 

 

 

 

 

 

 

 

 

DC power supply

 

Output voltage

: 13.8 V DC

Audio generator

Frequency range

: 300–3000 Hz

 

 

Current capacity

: 25 A or more

Output level

: 1–500 mV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measuring range

: 1–200 W

Attenuator

Power attenuation

: 50 or 60 dB

 

RF power meter

 

Frequency range

: 0.5–50 MHz

Capacity

: 150 W or more

 

 

 

 

(terminated type)

 

Impedance

: 50

 

 

 

 

 

 

Frequency range

: 0.5–30 MHz

 

 

 

SWR

: Less than 1.2 : 1

Standard signal

 

 

 

 

 

Output level

: 0.1 µV–32 mV

 

 

 

Frequency range

: 0.1–50 MHz

generator (SSG)

 

 

 

 

(–127 to –17 dBm)

 

Frequency counter

 

 

 

 

 

Frequency accuracy

: ±1 ppm or better

 

 

 

 

 

 

 

 

 

DC voltmeter

Input impedance

: 50 k/V DC or better

 

 

 

Sensitivity

: 100 mV or better

 

 

 

 

 

 

 

 

 

FM deviation meter

 

Frequency range

: DC–50 MHz

Oscilloscope

Frequency range

: DC–20 MHz

 

 

Measuring range

: 0 to ±5 kHz

Measuring range

: 0.01–20 V

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital multimeter

 

Input impedance

: 10 M/V DC or better

AC millivoltmeter

Measuring range

: 10 mV–10 V

 

 

 

 

 

 

 

 

• CONNECTION

Standard signal

 

generator

Attenuator

CAUTION!

DO NOT transmit

while

connector

an SSG is connected to

 

 

 

the antenna connector.

 

 

 

 

 

 

 

 

 

 

 

 

 

antennato

Distortion meter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Speaker

 

 

 

 

 

 

 

Ammeter

[MIC] connector

 

 

 

 

 

 

 

 

 

Audio

 

 

AC millivolt

 

 

 

generator

 

 

meter

 

 

 

_

 

 

+

_

+

iF7000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

8

 

to [CONTROLLER]

 

to [SP]

 

PTT

RC-26

FM deviation meter

Spectrum scope

RF power meter

Frequency counter

100 load

(SWR 2 dumy load)

DC power supply

5 - 1

Page 22
Image 22
Icom IC-F7000 service manual Adjustment Procedures, Preparation, Required Test Equipment, Connection, Ptt