5-3 PA AND FILTER UNITS ADJUSTMENT

 

ADJUSTMENT

ADJUSTMENT CONDITIONS

 

MEASUREMENT

 

VALUE

ADJUSTMENT

 

 

 

 

 

 

 

 

UNIT

 

LOCATION

UNIT

ADJUST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IDLING

1

• Operating frequency

: 12.2350 MHz

Rear

 

Connect

an ammeter

2.0 A

PA

R6304

 

CURRENT

 

• Mode

: J3E

panel

 

(10 A) between an

 

 

 

 

(For drive

 

• Apply no audio signal to the [MIC] con-

 

 

external power supply

 

 

 

 

FETs)

 

nector.

 

 

 

and the transceiver.

 

 

 

 

 

 

 

• Disconnect J6702.

 

 

 

 

 

 

 

 

 

 

 

 

 

• Preset R6304 and R6412 on the PA

 

 

 

 

 

 

 

 

 

 

 

 

unit to max. counter clockwise.

 

 

 

 

 

 

 

 

 

 

 

 

• Preset R6515 on the PA unit to max.

 

 

 

 

 

 

 

 

 

 

 

 

clockwise.

 

 

 

 

 

 

 

 

 

 

 

 

 

• Connect a dummy load or RF power

 

 

 

 

 

 

 

 

 

 

 

 

meter to the [ANT] connector.

 

 

 

 

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(For final

2

• Transmitting

 

 

 

 

 

 

0.7 A

 

R6412

 

transistors)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• After adjustment, connect J6701 to the PA unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWR

1

• Operating frequency

: 22.0000 MHz

Rear

 

Connect an RF power

90 W

Audio

Output

 

DETECTOR

 

• Mode

: J3E

panel

 

meter to

the

[ANT]

 

gen-

level

 

 

 

 

• Connect the CP7332 (FOR line) on

 

 

connector.

 

 

erator

 

 

 

 

 

the FILTER unit to ground.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

• Connect an audio

generator to the

FIL-

 

Connect

a DC

volt-

Minimum level

FIL-

C7275

 

 

 

 

[MIC] connector and set as:

TER

 

meter to

the

check

 

TER

 

 

 

 

 

Frequency

: 1.5 kHz

 

 

point, CP7331.

 

 

 

 

 

 

 

 

Level

: OFF

 

 

 

 

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• After adjustment, disconnect CP7332 (FOR line) on the FILTER unit from ground.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 - 5

Page 26
Image 26
Icom IC-F7000 service manual PA and Filter Units Adjustment