5-3 PA AND FILTER UNITS ADJUSTMENT
| ADJUSTMENT | ADJUSTMENT CONDITIONS |
| MEASUREMENT |
| VALUE | ADJUSTMENT | ||||||
|
|
|
|
|
|
|
| ||||||
UNIT |
| LOCATION | UNIT | ADJUST | |||||||||
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
| IDLING | 1 | • Operating frequency | : 12.2350 MHz | Rear |
| Connect | an ammeter | 2.0 A | PA | R6304 | ||
| CURRENT |
| • Mode | : J3E | panel |
| (10 A) between an |
|
|
| |||
| (For drive |
| • Apply no audio signal to the [MIC] con- |
|
| external power supply |
|
|
| ||||
| FETs) |
| nector. |
|
|
| and the transceiver. |
|
|
| |||
|
|
|
| • Disconnect J6702. |
|
|
|
|
|
|
|
|
|
|
|
|
| • Preset R6304 and R6412 on the PA |
|
|
|
|
|
|
|
| |
|
|
|
| unit to max. counter clockwise. |
|
|
|
|
|
|
|
| |
|
|
|
| • Preset R6515 on the PA unit to max. |
|
|
|
|
|
|
|
| |
|
|
|
| clockwise. |
|
|
|
|
|
|
|
|
|
|
|
|
| • Connect a dummy load or RF power |
|
|
|
|
|
|
|
| |
|
|
|
| meter to the [ANT] connector. |
|
|
|
|
|
|
|
| |
|
|
|
| • Transmitting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (For final | 2 | • Transmitting |
|
|
|
|
|
| 0.7 A |
| R6412 | |
| transistors) |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| • After adjustment, connect J6701 to the PA unit. |
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| ||
| SWR | 1 | • Operating frequency | : 22.0000 MHz | Rear |
| Connect an RF power | 90 W | Audio | Output | |||
| DETECTOR |
| • Mode | : J3E | panel |
| meter to | the | [ANT] |
| gen- | level | |
|
|
|
| • Connect the CP7332 (FOR line) on |
|
| connector. |
|
| erator |
| ||
|
|
|
| the FILTER unit to ground. |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| 2 | • Connect an audio | generator to the | FIL- |
| Connect | a DC | volt- | Minimum level | FIL- | C7275 |
|
|
|
| [MIC] connector and set as: | TER |
| meter to | the | check |
| TER |
| |
|
|
|
| Frequency | : 1.5 kHz |
|
| point, CP7331. |
|
|
|
| |
|
|
|
| Level | : OFF |
|
|
|
|
|
|
|
|
|
|
|
| • Transmitting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
| • After adjustment, disconnect CP7332 (FOR line) on the FILTER unit from ground. |
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 - 5