5-3  PA AND FILTER UNITS ADJUSTMENT
| 
 | ADJUSTMENT | ADJUSTMENT CONDITIONS | 
 | MEASUREMENT | 
 | VALUE | ADJUSTMENT | ||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||||
| UNIT | 
 | LOCATION | UNIT | ADJUST | |||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | IDLING | 1 | • Operating frequency | : 12.2350 MHz | Rear | 
 | Connect | an ammeter | 2.0 A | PA | R6304 | ||
| 
 | CURRENT | 
 | • Mode | : J3E | panel | 
 | (10 A) between an | 
 | 
 | 
 | |||
| 
 | (For drive | 
 | • Apply no audio signal to the [MIC] con- | 
 | 
 | external power supply | 
 | 
 | 
 | ||||
| 
 | FETs) | 
 | nector. | 
 | 
 | 
 | and the transceiver. | 
 | 
 | 
 | |||
| 
 | 
 | 
 | 
 | • Disconnect J6702. | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | • Preset R6304 and R6412 on the PA | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | unit to max. counter clockwise. | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | • Preset R6515 on the PA unit to max. | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | clockwise. | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | • Connect a dummy load or RF power | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | meter to the [ANT] connector. | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | • Transmitting | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | (For final | 2 | • Transmitting | 
 | 
 | 
 | 
 | 
 | 
 | 0.7 A | 
 | R6412 | |
| 
 | transistors) | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | • After adjustment, connect J6701 to the PA unit. | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | SWR | 1 | • Operating frequency | : 22.0000 MHz | Rear | 
 | Connect an RF power | 90 W | Audio | Output | |||
| 
 | DETECTOR | 
 | • Mode | : J3E | panel | 
 | meter to | the | [ANT] | 
 | gen- | level | |
| 
 | 
 | 
 | 
 | • Connect the CP7332 (FOR line) on | 
 | 
 | connector. | 
 | 
 | erator | 
 | ||
| 
 | 
 | 
 | 
 | the FILTER unit to ground. | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 2 | • Connect an audio | generator to the | FIL- | 
 | Connect | a DC | volt- | Minimum level | FIL- | C7275 | 
| 
 | 
 | 
 | 
 | [MIC] connector and set as: | TER | 
 | meter to | the | check | 
 | TER | 
 | |
| 
 | 
 | 
 | 
 | Frequency | : 1.5 kHz | 
 | 
 | point, CP7331. | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | Level | : OFF | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | • Transmitting | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | 
 | 
 | 
 | • After adjustment, disconnect CP7332 (FOR line) on the FILTER unit from ground. | 
 | 
 | |||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
5 - 5