5-4 RECEIVER ADJUSTMENTS
”TOTAL GAIN”,
ADJUSTMENT | ADJUSTMENT CONDITIONS |
| MEASUREMENT | VALUE | ADJUSTMENT | |||||
|
|
|
|
|
| |||||
UNIT |
| LOCATION | UNIT | ADJUST | ||||||
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| |
NOISE NULL | 1 | • Operating frequency | : 0.5 MHz | Front |
| Connect an AC milli- | Minimum output | MAIN | R217, | |
POINT |
| • Mode | : A3E | panel |
| voltmeter to | the [SP] | level |
| R218 |
|
| • Preset L209 parallel to top edge of its |
|
| jack with a 4 Ω | dummy |
|
|
| |
|
| chassis. |
|
|
| load. |
|
|
|
|
|
| • Preset L401, L403, L404, L405 and |
|
|
|
|
|
|
| |
|
| L801 to max. counter clockwise. |
|
|
|
|
|
|
| |
|
| • Set the standard signal generator to |
|
|
|
|
|
|
| |
|
| OFF (no signal output). |
|
|
|
|
|
|
| |
|
| • Receiving |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
RECEIVER | 1 | • Operating frequency | : 13.9210 MHz | Front |
| Connect an AC milli- | Maximum out- | MAIN | L207, | |
GAIN |
| • Mode | : J3E | panel |
| voltmeter to | the [SP] | put level |
| L208, |
|
| • Connect a standard signal generator |
|
| jack with a 4 Ω | dummy |
|
| L210, | |
|
| to the [ANT] connector and set as: |
|
| load. |
|
|
| L211 | |
|
| Frequency | : 13.9210 MHz |
|
|
|
|
|
|
|
|
| Level | : 0.5 µV* |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| Modulation | : OFF |
|
|
|
|
|
|
|
|
| • Receiving |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
TOTAL GAIN | 1 | • While pushing | • Push the [OK] switch to write the adjustment value in the memo- | |||||||
|
| switch and | ry. |
|
|
|
|
|
| |
|
| then turn power ON. |
|
|
|
|
|
|
|
|
|
| • Push [2] switch to enter the RX adjust- |
|
|
|
|
|
|
| |
|
| ment mode. |
|
|
|
|
|
|
|
|
|
| • Connect a standard signal generator |
|
|
|
|
|
|
| |
|
| to the [ANT] connector and set as: |
|
|
|
|
|
|
| |
|
| Frequency | : 13.9210 MHz |
|
|
|
|
|
|
|
|
| Level | : 320 µV* |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| Modulation | : OFF |
|
|
|
|
|
|
|
|
| • Receiving |
|
|
|
|
|
|
|
|
|
|
|
| |||||||
| 1 | • Set the standard signal generator to | • Push the [OK] switch to write the adjustment value in the memo- | |||||||
|
| OFF (no signal output). | ry. |
|
|
|
|
|
| |
|
|
|
| |||||||
| 2 | • Set the standard signal generator as: | • Push the [OK] switch to write the adjustment value in the memo- | |||||||
|
| Frequency | : 13.9210 MHz | ry. |
|
|
|
|
|
|
|
| Level | : 10 mV* |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| • Receiving |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.
5 - 7