TRANSMITTER ADJUSTMENTS–Continued

ADJUSTMENT

ADJUSTMENT CONDITIONS

 

MEASUREMENT

VALUE

ADJUSTMENT

 

 

 

 

 

 

UNIT

 

LOCATION

UNIT

ADJUST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IC-APC

1

 

• Operating frequency

: 13.810 MHz

Rear

 

Connect

an ammeter

24.0 A [AUS]

PA

R6516

 

 

 

 

• Mode

: J3E

panel

 

(50 A)

between an

28.0 A [OTH]

 

 

 

 

 

 

• Set the audio generator as:

 

 

external power supply

 

 

 

 

 

 

 

Frequency

: 1.5 kHz

 

 

and the

transceiver.

 

 

 

 

 

 

 

Level

: 100 mV

 

 

 

 

 

 

 

 

 

 

 

• Preset R6516 on the PA unit to center

 

 

 

 

 

 

 

 

 

 

 

position.

 

 

 

 

 

 

 

 

 

 

 

 

• Connect the CP7332 (FOR line) on

 

 

 

 

 

 

 

 

 

 

 

the PLL unit to ground.

 

 

 

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• After adjustment, disconnect CP7332 (FOR line) on the PLL unit from ground.

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• PA UNIT TOP VIEW

R6516

Ic-APC adjustment

• PLL UNIT BOTTOM VIEW

CP7332

Connect to ground

RC-26 FRONT PANEL

[VOL] DIAL

[OK]

IC-F7000 BOTTOM VIEW

PLL unit

5 - 10

Page 31
Image 31
Icom IC-F7000 service manual Ic-Apc, VOL Dial