TRANSMITTER ADJUSTMENTS–Continued
ADJUSTMENT | ADJUSTMENT CONDITIONS |
| MEASUREMENT | VALUE | ADJUSTMENT | |||||||
|
|
|
|
|
| |||||||
UNIT |
| LOCATION | UNIT | ADJUST | ||||||||
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
| • Operating frequency | : 13.810 MHz | Rear |
| Connect | an ammeter | 24.0 A [AUS] | PA | R6516 | |
|
|
|
| • Mode | : J3E | panel |
| (50 A) | between an | 28.0 A [OTH] |
|
|
|
|
|
| • Set the audio generator as: |
|
| external power supply |
|
|
| ||
|
|
|
| Frequency | : 1.5 kHz |
|
| and the | transceiver. |
|
|
|
|
|
|
| Level | : 100 mV |
|
|
|
|
|
|
|
|
|
|
| • Preset R6516 on the PA unit to center |
|
|
|
|
|
|
| |
|
|
|
| position. |
|
|
|
|
|
|
|
|
|
|
|
| • Connect the CP7332 (FOR line) on |
|
|
|
|
|
|
| |
|
|
|
| the PLL unit to ground. |
|
|
|
|
|
|
| |
|
|
|
| • Transmitting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
| • After adjustment, disconnect CP7332 (FOR line) on the PLL unit from ground. |
|
| ||||||
| 2 |
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• PA UNIT TOP VIEW
R6516
• PLL UNIT BOTTOM VIEW
CP7332
Connect to ground
• RC-26 FRONT PANEL
[VOL] DIAL | [OK] |
• |
PLL unit |
5 - 10