29
5
SCAN OPERATION
■Auto memory write scan
Auto memor y wr ite scan does the same as the programmed
scan and then writes paused signal frequencies into memory
channels of a specified memory bank. Scan edges must be
programmed in advance. (p. 28)
DUsing the multi-function receiver screen
qMake sure the squelch is set to the threshold point. (closed
condition)
wClick the [SET] button to call up the setting screen if it is
not displayed.
eClick the [Program SCAN] tab to show the program list.
rSelect the programmed scan edges to be scanned with the
mouse, then click the [Auto MW SCAN] tab.
tSelect a memory bank to be written.
•To clear the selected memory bank contents, click [All Clear].
yClick the [AUTO] button to start auto memory write scan.
•“AUTO”flashes while scanning.
uTo cancel the scan, click [STOP] or [AUTO].
DUsing the simple function receiver screen
qMake sure the squelch is set to the threshold point. (closed
condition)
wCall up the setting screen if it is not displayed.
•Click the [MENU] button and select the ‘Function Setting (SET).’
•When the scan controller screen is in use, click the [SET] button
on the screen.
eClick the [Program SCAN] tab to show the program list.
rSelect the programmed scan edges to be scanned with the
mouse, then click the [Auto MW SCAN] tab.
tSelect a memory bank to be written.
•To clear the selected memory bank contents, click [All Clear].
yCall up the scan controller screen if it is not displayed.
•Click the [MENU] button and select the ‘Scan Controller.’
uClick the [AUTO] button to start auto memory write scan.
•“Auto MW SCAN”flashes while scanning.
iTo cancel the scan, click [STOP] or [AUTO].
[AUTO]
[STOP]
[SET]