5SCAN OPERATION

Scan resume condition

When receiving a signal, scan automatically pauses on that
signal.The scan resume condition sets the time that the scan
pauses before resuming or whether scan stops instead of
pausing.
qCall up the setting screen if it is not displayed.
For the multi-function receiver screen, click the [SET] button.
For the simple function receiver screen, click the [MENU] button
and select the Function Setting (SET).When the scan controller
screen is in use, click the [SET] button on the screen.
wClick the [SCAN Delay] tab, then click to select a resume
condition from [DELAY Timing].
(a) Pause until Signal disappears
Scan pauses when receiving a signal and remains
paused until the signal disappears.
(b) Delay V olume
When setting a delay time using the [DELAY] control
(multi-function receiver screen) or [DELAY] scroll bar
(scan controller screen), scan pauses when receiving a
signal and then resumes after the specied delay.
(c) SCAN Stop
When a signal is received during scan, scan stops and
does not resume.
eClick to select a restart delay time from [Restart Delay].
This setting is valid when selecting (a) or (b) above.
(a) 0 Sec.
Scan resumes immediately after the signal disappears.
(b) 1 Sec.
Scan resumes 1 sec. after the signal disappears.
(c) 2 Sec.
Scan resumes 2 sec. after the signal disappears.
rClick the close (["]) button to close the setting screen.
[DELAY][DELAY]