SYMPTOM

CAUSE

REMEDY

Automatic Disc Brake:

 

 

Brake fails to release.

Low air supply pressure.

Ensure air pressure at inlet to disc brake is at least 50 psig (3.4 bar/340

 

 

kPa).

 

 

 

 

Leaking piston seals.

Inspect brake breather. If air escapes from brake breather when attempting

 

 

to release brake, replace brake seals.

 

 

 

 

No release pressure at brake

Check for proper operation of winch controls.

 

port.

 

 

 

 

 

Sticking brake piston.

Apply 50 psig (3.4 bar/340 kPa) to brake release port and check for brake

 

 

disc movement. (Brake discs can be viewed through brake breather hole.)

 

 

If brake discs do not move, disassemble and inspect disc brake as

 

 

described in “MAINTENANCE” section.

 

 

 

MHD56037 - Edition 5