Inova OnTime Digital Clock Owner's Manual
Section 8: Troubleshooting
The following table contains several trouble conditions you may encounter with the OnTime Digital Clock and the recommended actions to take to correct the problem.
Note: The
Condition |
| Solution |
Clock Face Dark | 1. | Verify that an Ethernet PoE power injector is present (if required) |
|
| and is operating. |
| 2. | Reboot the clock by disconnecting the data cable, counting to five, |
|
| and reconnecting the cable. |
|
|
|
Clock Shows Incorrect Time | 1. | If the Service Light is illuminated (see below). |
| 2. | If the minutes past the hour are correct, verify the Time Zone and |
|
| Daylight Saving Time settings. |
|
|
|
DHCP Message on Clock Face | 1. | The clock has failed to receive an IP address from the DHCP server. |
| 2. | Contact your IT group responsible for DHCP service. |
| Note: that the clock is reachable through its fixed | |
| for diagnostic or | |
| 169.254.0.100 | |
|
| |
Service Light Blinking | The service light is located at the bottom right of the clock face. | |
| 1. | There is an active telnet configuration session in progress on the |
|
| clock. |
|
| |
Service Light On | The service light is located at the bottom right of the clock face. | |
| 1. | Reboot the clock to verify that it properly receives a DHCP address. |
| 2. | Verify that the SNTP server configuration is valid as the service light |
|
| will also be illuminated after several missed updates. Refer to the |
|
| “Testing the Time Server Synchronization” section in Section 7: Telnet |
|
| Configurations |
|
| |
Determine the IP Address of a | If the IP Address of each clock has not been recorded during installation, | |
Clock | it is suggested to follow this power cycle procedure. | |
| 1. | Lift UP gently on the unit to free the keyholes at the rear of the clock |
|
| from the mounting hardware. |
| 2. | Disconnect the network cable from the clock in question and count to |
|
| five. |
| 3. | Replace the network cable and watch the face of the Inova Digital |
|
| Clock. |
| It will display its IP address as it boots. | |
|
| |
Clock showing | No Time Server/Time Server down | |
|
| |
Other Problems | Refer to the FAQ at www.buyinova.com under the support tab. | |
|
|
|
Table 6: Troubleshooting OnTime Digital Clock