TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

WHAT TO DO

Water is not cold.

• No power to unit.

• Make sure the circuit breaker or fuses are

 

 

functioning properly.

 

• The unit is unplugged.

• Make sure the unit is connected to a properly grounded

 

 

electric outlet.

 

• The electric outlet is inoperative.

• Check that the outlet is not switched off.

 

• Copper tubes connected incorrectly.

• Switch copper tube connections.

 

• Cold water in the chilled water tank is still being chilled.

 

• The unit has not had sufficient time to

 

Wait 15 minutes and check temperature once again.

 

chill the water.

 

 

• Check that the temperature control knob is set to the

 

 

maximum cold setting.

 

 

 

Cold water drips or

• Tube is blocked.

• Check that tubes are not kinked, twisted or pinched.

sputters from spout.

 

• Unscrew spout end piece and clean out any debris.

 

 

 

 

 

Water does not flow

• Insufficient water supply

• Check the supply valve to ensure that is fully open and

from spout.

 

there are no obstructions in the water line reducing the

 

 

pressure below 30 psi (i.e., a poorly mounted saddle

 

 

valve, a clogged water filter, or a partially opened

 

 

shut-off valve).

 

 

• Check to see if chilled water tank is improperly connected

 

 

to hot water supply line. If so, attach to cold water line.

 

• The spout is blocked.

• Unscrew spout end piece and clean out any debris.

 

 

 

Water is dripping

• Debris in the water line may be

• Unscrew spout end piece and clean out any debris.

from the spout/vent

in the faucet valve seat causing a

• Activate faucet lever 7-10 times to flush faucet & lines.

constantly.

slow water leak.

 

 

 

 

Divided stream.

• Debris in the end piece.

• Unscrew spout end piece and clean out any debris.

 

 

 

Unpleasant taste.

• Chilled water tank requires purging.

• If chilled water has not been dispensed for 3 or more days, or

 

 

if fewer than 3 cups per day are dispensed, the chilled water tank

 

 

should be purged. Run cold only faucet for 3 minutes to purge

 

 

chilled water tank. Wait 1 hour before dispensing fresh water.

 

 

 

FILTRATION ISSUES (Filtration available as an option)

 

 

 

Water taste or odor

• Filter needs to be flushed out

• Activate the faucet lever and run until the water is cold.

 

• Life of filter has expired

If there is no change, replace filter cartridge.

 

 

 

New filter leaks or

• Head and bracket not fully rotated

• Remove, inspect, reinstall filter cartridge.

doesn’t fit

• Filter O-ring breach

• Remove new filter, replace with old filter. Check operation.

 

 

 

If OK, reinstall new filter and recheck operation.

No water flow or

• Life of filter has expired

• Replace filter cartridge. See page 11.