CARE AND USE
Electric Shock Hazard: To prevent electrical shock, disconnect power before servicing unit. Use only a properly grounded and polarized electric outlet.
ADJUSTING WATER TEMPERATURE
PROPERTY DAMAGE
The temperature on the chilled water tank is controlled by the temperature control knob
on the front of the unit.
■For colder water – Turn the control knob clockwise. Allow 60 mins.
| r |
e | |
ld |
|
o |
|
C |
|
water
■ Regularly inspect the unit for any signs of |
leakage. If there are signs of water damage, |
immediately remove the unit from service. |
■ To avoid water damage from leakage, |
replace all cut, loose or split tubing. |
■ A drain pan, plumbed to an appropriate |
drain or outfitted with a leak detector, |
■ For less cold water – 

Turn the control knob counterclockwise.
■To shut down the chilled water tank – Turn control knob counterclockwise
to the “OFF” position.
SEASONAL STORAGE/DRAINAGE
Anytime the chilled water tank will not be used for an extended period, or if temperature is below freezing, unplug and drain the unit.
■Disconnect power from unit.
■Shut the cold water supply off at the valve.
■Open cold only faucet to relieve pressure from the chilled water tank.
■Disconnect the inlet/outlet water lines attached to the chilled water tank.
■Drain water from the chilled water tank by tipping it on its left side (power cord side) and allow water to run into a large container.
■Once drained, set unit in its normal upright position for storage.
■To put the chilled water tank back into service, reconnect the water lines (see Pages
■Open the cold water faucet until water runs from the faucet.
■Plug in the unit and set control knob to desired temperature.
CLEANING THE TANK AND FAUCET
■Only use mild cleaners to clean the faucet and plastic components.
■Cleaners with acids, abrasives, alkaline or organic solvents will result in deterioration of the plastic components and void the warranty.
should be used in those applications where |
any leakage could cause property damage. |
FILTER GUIDE AND REPLACEMENT
(Filtration available as an option)
Replace filter cartridge when there is an obvious decrease in water flow to the faucet or if there is an objectionable taste or odor to the water.
When the inlet and outlet ports have been closed and the filter’s internal pressure has been relieved, water (about 2 oz) will discharge from vent line.
If the new filter cartridge cannot be inserted, insert the old one and turn until it stops, remove it and then retry the new cartridge.
Carbon filters should be replaced within 12 months.
Filter replacement instructions:
Replace with an InSinkErator® filter.
Place pan or dish towel under the filter to catch water drainage during change.
Slowly turn the cartridge
Pull cartridge straight down and discard.
Insert new cartridge into filter head.
Top surface of cartridge will become flush
with the bottom of the filter head when fully engaged.
Turn the cartridge clockwise until it stops (1/4 turn).
Align the in/out arrow on the head and bracket assembly to the in/out arrow on the cartridge.
Open faucet to expel trapped air.
Run water for 3 minutes before usage.
11