10. Test the Water Connection

Test the water connection to see if it is watertight. If it is not, relieve water pressure by turning off the water supply, and adjust or tighten fittings as necessary. Note that water must flow from the dispenser faucet to test all connections.

Note: Ensure both hot and cold side are checked on the HC model.

DO NOT PLUG IN THE TANK.

11. Plug in the Tank

Once the tank is plugged in, it will take between 10 and 15 minutes for the water to reach its target temperature. During the heating cycle, you can expect to hear gurgling or hissing sounds within the tank. This is normal.

Electric Shock Hazard. This appliance must be properly grounded. Using an ungrounded appliance can result in serious injury or death from electric shock. Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance. If it will not fit in the outlet, have the proper outlet installed by a qualified electrician.

Care and Use

To Adjust the Thermostat:

Electric Shock Hazard. To prevent electrical shock, disconnect power before removing access cover to service the thermostat.

Scalding Hazard. Do not allow water to boil. May result in severe burns.

On the front of the tank there is an access panel. Unscrew the holding screw and locate the temperature control dial.

The thermostat is pre-set at the factory to approximately 190˚ F. If a thermostat adjustment is required, turn knob clockwise 1/2 dial mark to increase the water temperature and counterclockwise 1/2 dial mark to decrease the water temperature.