To Reset the Thermal Cut-Out:

Care and Use

Once you have made the adjustment, actuate the dispenser handle for 20 seconds and allow the water to re-heat at the new temperature setting. If the temperature is still too hot or too cold, continue to make slight adjustments. At no time should the water in the tank be allowed to boil. Boiling is indicated by water and/or steam discharged from the faucet without actuating the handle.

Replace the access panel.

To Reset the Thermal Cut-Out:

In the event the unit stops heating or fails to heat the water, check the thermal cut- out as it may have tripped. Open the access panel on the front of the tank with a screwdriver. Locate the thermal cut-out reset button and press it to reset the switch.

Replacement Filter Guidelines: It is essential that regular filter replacement be carried out for this product to perform as advertised. Replace the cartridge every three months or when there is an obvious decrease in water flowing from the faucet or when objectionable taste and/or odors return. Replace with In-Sink-Erator®brand filter cartridges. Flush new cartridges for 3 minutes before first use.

To Replace the Filter: Electric Shock Hazard. To prevent electrical shock, disconnect power before servicing unit. Use only a properly grounded and polarized electric outlet.

To Replace the Filter:

Place a pan or dish-towel under the filter to catch water drainage during the cartridge change.

Slowly turn cartridge counter-clockwise completely until it stops (approx. 90º or 1/4 turn). At this position, the inlet and outlet ports have been closed and the filter’s internal pressure has been relieved. Approximately 2 oz. of water will be discharged from the vent line. Pull used cartridge straight out and discard.

Insert new cartridge into filter head. Top surface of cartridge will become flush with bottom of filter head when fully engaged. Turn cartridge clockwise until it stops (approx 90º or 1/4 turn). If the new filter cartridge cannot be inserted, insert the old filter cartridge and turn completely until it stops and the arrow on the head and bracket assembly aligns with the in/out arrow on the cartridge.

Open hot water faucet to expel trapped air and allow water to run 3 minutes.