1, 0, 30

Data Mode AT COMMANDS

Table 18. Data Mode Command Descriptions (Continued)

Command

Default

 

Description

 

 

 

 

 

Break Handling: Controls break handling in error control operation. It accepts three numeric

 

 

subparameters:

 

 

Syntax:

 

 

 

+EB = <break selection>, <timed>, <default length>

 

 

<break selection> specifies the type of break to be signaled to the remote DCE upon detecting one from

 

 

the local DTE.

 

 

0

Ignore Break (do not signal to remote DCE)

 

 

1

Non-expedited, non-destructive

 

 

2

Expedited, non-destructive

+EB

1, 0, 30

3

Expedited and destructive

 

 

<timed> specifies if the break signal to be signaled to the remote DCE is timed or not.

 

 

0

Sent without a break signal length

 

 

1

Sent with break signal length

 

 

<default length> specifies the amount of time in tens of milliseconds that a break should be signaled to

 

 

the local DTE when an indication of a break is received from the remote DCE without explicitly indicated.

 

 

0

Do not deliver received break to DTE

 

 

1

Default break length 0.01 to 2.54 seconds. Used for default to signal DTE when break

 

 

 

received from the remote DCE without break length

 

 

Controls the use of breaks in V.42.

 

 

 

 