Data Mode AT COMMANDS
Table 18. Data Mode Command Descriptions (Continued)
Command Default | Description |
Synchronous Access Mode Configuration: controls the manner of operation of the Synchronous Access Mode in the DCE (if present).
Syntax:
+ESA=[<trans_idle>[,<framed_idle>[,<framed_un_ov>[,<hd_auto>[,<crc_type>[,<nrzi_en>[,<syn1>[,<sy n2>]]]]]]]]
<trans_idle> specifies the bit sequence transmitted by the DCE when a transmit data buffer underrun condition occurs, while operating in Transparent
0In Transparent
1In Transparent
2In Transparent
<framed_idle> specifies the bit sequence transmitted by the DCE when a transmit data buffer underrun condition occurs immediately after a flag, while operating in Framed
0In Framed
1In Framed
<framed_un_ov> specifies the actions undertaken by the DCE when a transmit data buffer underrun or overrun condition occurs immediately after a
0In Framed
1In Framed
<hd_auto> specifies whether or not, in V.34 half duplex operation, additional procedures besides those 0, 0, 1, specified in clause 12/V.34 shall be performed by the DCE when switching from primary channel to
,0, 0, secondary channel operation, and vice versa.
0, | 0 | When switching between primary and secondary channel operation in V.34 half duplex, the |
| ||
|
| DCE only executes those procedures defined in clause 12/V.34 |
| 1 | When switching between primary and secondary channel operation in V.34 half duplex, the |
|
| DCE executes additional procedures as described in 8.8.5 besides those defined in clause |
|
| 12/V.34 |
| <crc_type> specifies the CRC polynomial used while operating in Framed | |
| 0 | CRC generation and checking disabled |
| 1 | In Framed |
|
| the transmit direction, and checked by the DCE in the receive direction |
| 2 | In Framed |
|
| the transmit direction, and checked by the DCE in the receive direction |
| <nrzi_en> specifies if Non Return to Zero Inverted (NRZI) encoding is to be used by the DCE for transmit | |
| and receive data. | |
| 0 | NRZI encoding and decoding disabled |
| 1 | NRZI encoding enabled in the DCE in the transmit direction, and NRZI decoding enabled in |
|
| the DCE in the receive direction |
| <syn2> specifies the octet value(s) to be used while performing | |
| When <trans_idle>=0, specifies the | |
|
| When <trans_idle>=1, specifies the |
|
| When <trans_idle>=2, specifies first 8 bits of |
|
| by the DCE |
| <syn1> specifies the octet value(s) to be used while performing | |
| When <trans_idle>=2, specifies last 8 bits of | |
|
| by the DCE |
NOTE: An asterisk (*) denotes the
536EX Chipset Developer’s Manual | 49 |
Intel Confidential