Intel J2 650 Installing the Intel Matrix Storage Manager Software, Hot Swapping RAID 1 drives

Models: J2 650

1 78
Download 78 pages 3.56 Kb
Page 61
Image 61
2.Press the S key to Specify Additional Device.

Perform the following steps to install the Intel Matrix Storage Manager driver during operating system setup:

1.Press the F6 key when prompted in the status line with the Press F6 if you need to install a third party SCSI or RAID driver message. This message appears at the beginning of Windows XP setup (during text-mode phase).

Note: Nothing will happen immediately after pressing F6. Setup will temporarily continue loading drivers. You will then be prompted with a screen asking you to load support for mass storage device(s).

2.Press the S key to Specify Additional Device.

3.You will be prompted to Please insert the disk labeled Manufacturer-supplied hardware support disk into Drive A: When prompted, insert the floppy disk containing the following files: IAAHCI.INF, IAAHCI.CAT, IASTOR.INF, IASTOR.CAT, IASTOR.SYS, and TXTSETUP.OEM and press the Enter key.

4.After pressing Enter, you should be presented with a list of available SCSI Adapters. Select your controller from the list. The 650 uses the ICH8R driver.

5.The next screen should confirm your selected controller. Press the Enter key again to continue.

6.At this point, you have successfully F6'd in the Intel Matrix Storage Manager driver and Windows setup should continue. Leave the floppy disk in the floppy drive until the system reboots. Windows setup will need to copy the files from the floppy again to the Windows installation folders. Once Windows setup has copied these files again, you should then remove the floppy diskette so that Windows setup can reboot as needed.

7.During Windows setup, create a partition and file system on the RAID volume as you would on any physical disk.

Installing the Intel Matrix Storage Manager Software

Once XP is booted you can install the Intel Matrix Storage Manager by just running the iata82_enu.exe install program. Just answer “Next” to all questions and the software will install. The software should now be working. Please refer to Intel’s documentation for more information at manual70.pdf.

Hot Swapping RAID 1 drives

If a RAID 1 drive fails the Matrix Storage Manager will warn the user that a drive has failed. A small Icon appears as shown to indicate a drive has failed.

Drive Failed Icon in tray

650 System Manual (Draft)

61

Version 0.4 August 20, 2008

 

Page 61
Image 61
Intel J2 650 Installing the Intel Matrix Storage Manager Software, Hot Swapping RAID 1 drives, Drive Failed Icon in tray